LQ602 Transformer Frequency Response Analyzer (FRA) | Advanced Winding Diagnostics

Detect transformer winding faults accurately with the LQ602 FRA Tester. Industry-standard frequency response analysis for reliable assessment of core deformation, displacement & internal damage.


  • 1.Use high-speed, high integration microprocessor to sample and control.
    2.Use USB to connect the notebook PC and device.
    3.Communication wireless blue tooth interface between the laptop and instruments.
    4.Hardware cassette mechanism adopts DDS (from America), can correctly detect the breakdown :distortion, swell, shift, tilt, inter-turn short circuit deformation and contacting short circuit inter-phase.
  • 5.High-speed, dual channel, 16 bit A/D sampling (the wave from curve will change obviously if change the tapping switch during the field tests.).
    6.The software can adjust the output signal range, the maximum amplitude peak±10V.
    7.The computer automatically generating the test results to be Word document.
    8.Use precision, high stability components, the same phase repeat test, measurement repetition rate >99.5%.
    9.Finished circuit boards, surface specially treatment with anti-water pollution and harmful gases.
    10.The device with two measurement system: linear scan and sectional scan.
    11.Amplitude-frequency characteristic comply the national technical specifications.

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQ602 Transformer Frequency Response Analyzer: Precision Diagnostics for Transformer Integrity

The LQ602 Transformer Frequency Response Analyzer (FRA) is an advanced diagnostic instrument engineered to assess the mechanical and electrical integrity of transformer windings. Utilizing the globally recognized Frequency Response Analysis (FRA) methodology – the industry gold standard for internal fault detection – the LQ602 provides engineers with definitive data to identify subtle or significant damage within critical power assets.

How the LQ602 FRA Tester Works

The LQ602 measures minute changes in the characteristic electrical parameters of transformer windings across a wide frequency spectrum. By injecting low-voltage signals and analyzing the amplitude/phase response, it creates a unique "fingerprint" of the transformer's winding geometry and core condition. Deviations from baseline or reference fingerprints indicate potential internal faults, such as:

  • Winding deformation (radial or axial)

  • Core displacement or buckling

  • Shorted turns or open circuits

  • Loose clamping structures

  • Internal dielectric degradation

Key Features & Advantages

  1. Industry-Standard FRA Methodology: Implements the internationally accepted FRA technique trusted by utilities and testing laboratories worldwide for reliable internal fault assessment.

  2. High Accuracy & Repeatability: Delivers precise, repeatable measurements critical for confident fault identification and trending over time.

  3. Comprehensive Diagnostics: Detects even minor winding or core deformations long before catastrophic failures occur, enabling predictive maintenance.

  4. Portable & Rugged Design: Engineered for field use in substations, power plants, and industrial facilities.

  5. Intuitive Software: Powerful PC software simplifies measurement setup, data analysis, comparison against reference fingerprints, and comprehensive report generation.

  6. Safety Compliance: Designed for safe operation according to relevant electrical safety standards (e.g., IEC 61010).

Critical Applications

  • Preventive & Predictive Maintenance: Schedule repairs proactively based on winding condition.

  • Transformer Commissioning: Establish baseline fingerprints for future comparisons.

  • Post-Transport/Installation Checks: Verify no damage occurred during handling.

  • Post-Fault Investigation: Diagnose internal damage following through-faults or external events.

  • Life Extension Assessments: Evaluate the condition of aging transformer fleets.

Why Choose Frequency Response Analysis (FRA)?

FRA is uniquely sensitive to the physical geometry of transformer windings and core. Unlike electrical tests alone (e.g., turns ratio, winding resistance), FRA directly detects mechanical changes caused by short-circuit forces, transportation shock, or aging – the leading causes of internal transformer failure. The LQ602 makes this powerful diagnostic technique accessible and reliable.

The LQ602 Advantage: Confidence in Transformer Health

Investing in the LQ602 Transformer Frequency Response Analyzer empowers your team to:

  • Reduce Unplanned Outages: Identify developing faults before they cause failures.

  • Extend Asset Lifespan: Make informed repair/replace decisions.

  • Improve Safety: Prevent catastrophic transformer incidents.

  • Optimize Maintenance Costs: Focus resources where needed most.

  • Ensure Grid Reliability: Maintain critical power infrastructure integrity.