High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Dry Type

HFRS 270kV/270kVA Modular Dry Type Resonant System: Six-Stage Flexible Testing Solution

Complete specifications for the HFRS 270kV/270kVA six-module dry type resonant test system with flexible series/parallel configurations for high voltage equipment testing applications.


  • US$ 14,755.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HFRS 270kV/270kVA Modular Dry Type Resonant System: Six-Stage Flexible Testing Solution

Advanced six-module configuration providing unmatched flexibility with multiple voltage/current combinations through series and parallel connections of 45kV/45kVA dry type reactor units.

System Configuration Options

ConfigurationVoltageCurrentPowerInductance
6S (All Series)270kV1A270kVA792H
3S2P (3 Series × 2 Parallel)135kV2A270kVA198H
Single Module45kV1A45kVA132H

Technical Specifications

  • Base Module: 45kV/45kVA dry type reactor

  • Total Modules: 6 (320kg total system weight)

  • Frequency Range: 30-300Hz

  • Continuous Operation: 60 minutes at rated power

  • AC Withstand: 110% of rated voltage

  • Temperature Rise: ≤65K after 60 minutes operation

  • Cooling Method: Natural air convection

Design Advantages

Modular Flexibility

  • Multiple configuration options (series/parallel combinations)

  • Individual module weight: 50kg (easy handling)

  • Quick-connect bushing system

Dry Type Technology

  • Epoxy tube insulation system

  • No flammable liquids - safer operation

  • Lower maintenance requirements

  • Environmentally friendly

Thermal Management

  • Optimized airflow design

  • Temperature rise within 65K at full load

  • Automatic thermal protection

Performance Comparison

FeatureHFRS Dry TypeConventional Oil Type
Max Voltage270kVTypically 150kV
Weight320kg600kg+
MaintenanceAnnual inspectionQuarterly oil tests

Typical Applications

High Voltage Cable Testing

  • 270kV AC withstand testing

  • Partial discharge measurement

Transformer Testing

  • Winding resistance measurements

  • Frequency response analysis

GIS Commissioning

  • Gas-insulated switchgear testing

  • Three-phase simultaneous testing

Operation & Maintenance

Installation Requirements

  • Minimum 3m clearance for 270kV operation

  • Well-ventilated area

  • Level mounting surface

Maintenance Schedule

  • Visual inspection before each use

  • Annual dielectric test

  • Five-year comprehensive evaluation