High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Cylinder Type

HFRS 800kV/16MVA Resonant Test System: Four-Stage Modular Solution for Ultra High Voltage Testing

Complete technical specifications of the HFRS 800kV/16MVA four-stage modular resonant test system with flexible configuration options for ultra high voltage equipment testing up to 880kV.


  • US$1.00; Negotiated Price
  • Lead time: 120days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HFRS 800kV/16MVA Resonant Test System: Four-Stage Modular Solution for Ultra High Voltage Testing

Modular Configuration Options

ConfigurationVoltagePowerInductanceCurrentWithstand
Single Reactor200kV4000kVar50H20A220kV/1min
2-Series400kV8000kVar100H40A440kV/1min
3-Series600kV12000kVar150H60A660kV/1min
4-Series800kV16000kVar200H80A880kV/1min

Key Performance Parameters

  • Frequency Range: 20-300Hz

  • Accuracy: <1% error

  • Quality Factor: Q≥40

  • Thermal Performance:

    • Winding temperature rise: ≤65K

    • Transformer oil rise: ≤55K

    • Epoxy tube surface: ≤40K

  • Duty Cycle: 30min ON / 60min OFF (max 3 cycles/day)

Advanced Structural Features

Modular Design

  • Four identical 200kV reactor modules

  • Mounted on 30kV insulated pedestal

  • Flexible series connection options

Core Technology

  • Segmented air gap iron core

  • High-purity copper windings

  • Precision inductance matching (±1%)

Cooling System

  • Oil-immersed self-cooling design

  • Epoxy cylinder structure

  • Integrated breather capsule

Field Deployment

  • Transport-optimized design (rail/road)

  • Integrated lifting hooks

  • Configuration-specific nameplates

Performance Advantages

FeatureHFRS SystemConventional Units
Maximum Voltage880kVTypically 650kV
Modular Flexibility4-stage configurationUsually fixed
Current CapacityUp to 80ATypically 40A max

Typical Applications

1. UHV Equipment Testing

  • 800kV+ transformer testing

  • GIS withstand verification

2. Long Cable Systems

  • Extra high voltage cable testing

  • Partial discharge measurement

3. Power Station Commissioning

  • Generator step-up transformer testing

  • Busbar system verification

Operational Guidelines

Safety Procedures

  • 15m minimum clearance for 800kV tests

  • Strict grounding protocol during reconfiguration

Maintenance Schedule

  • Pre-test insulation verification

  • Quarterly oil analysis

  • Annual full system calibration

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message