Power Cable Testing
35kV Power Cable Testing Laboratory Configuration
This optimized Faraday cage design enables efficient 35kV cable testing with space-saving external placement of the resonant test system while maintaining precise measurement conditions.
Shielded Test Enclosure Specifications
Component | Dimensions | Quantity |
---|---|---|
Main Faraday Cage | 10m × 8m × 5m (H) | 1 |
Cable Access Door | 4m × 4m | 1 |
Operator Entry Door | 1.9m × 0.9m | 1 |
Control Room | 3.0m × 2.5m × 2.8m | 1 |
Cable Handling System | 10 ton capacity with rails | 1 set |
Test System Architecture
Externally Located Equipment
HTKS 150kV/2500kVA Resonant System
Tank-type compact design
Connected via shielded HV bushing
Water Conditioning Unit
Control Room with shielded observation window
Internal Test Area Components
150kV cable test terminations (oil/water type)
HV filter bank
Injection capacitor system
Cable drum with lead rail
Safety Clearance: 1.0-1.2m around all HV terminals
Key Design Advantages
Space Efficiency
40% smaller footprint than conventional designs
External placement of heavy resonant system
Optimized cable handling workflow
Measurement Accuracy
<2pC partial discharge sensitivity
80dB EMI shielding effectiveness
Dedicated HV filtering
Typical Test Procedure
Cable loading onto 10-ton trolley system
Termination connection in test area
System energization from control room
AC withstand voltage testing
Partial discharge measurement
Performance Specifications
Voltage Rating: 150kV (35kV cable testing)
Frequency Range: 30-300Hz
Ground Resistance: <1Ω
Floor Loading: 1500kg/m²
Temperature Control: 20±5°C
Configuration Options
Higher voltage versions (up to 500kV)
Automated cable handling systems
Integrated PD mapping software
Mobile test solutions