Cylinder Type
HFRS 260kV/10000kVA Precision Resonant Test System
Designed for demanding field testing applications, the HFRS 260kV/10000kVA system combines laboratory-grade 30H±2% inductance accuracy with rugged iron-shell construction for reliable on-site operation.
Key Performance Specifications
Rated Output: 260kV at 38.5A (10MVA)
Voltage Endurance: 286kV for 1 minute
Inductance Precision: 30H ±2%
Frequency Range: 25-300Hz
Engineering Excellence
Core Technical Parameters
Quality Factor: Q≥65-120 across frequency range
Thermal Performance:
80K maximum winding temperature
55K transformer oil limit
Duty Cycle: 1hr ON / 1hr OFF (max 3 cycles/day)
Enhanced Cooling System
Feature | This System | Epoxy Designs |
---|---|---|
Heat Dissipation | 55K max oil temp | 65K typical |
Duty Cycle Capacity | 3 full cycles/day | 2 cycles typical |
Military-Grade Construction
Robust Mechanical Design
Iron-core segmented air gap with:
Oxygen-free copper windings
Precision 30H±2% inductance
Iron-shell oil tank provides:
40% better cooling than epoxy
Integrated breather capsule
Transport Optimized
Vibration-tested per IEC 61373 for:
2000km railway transport
1000km highway movement
260kV-rated lifting hooks with:
Load monitoring
Anti-sway protection
Certification & Compliance
Meets IEC 60060-1 insulation standards
Oil standards per IEC 60296
Transport certified per IEC 61373 Category 1
Key Advantages
Precision Inductance: 30H±2% for accurate tuning
Enhanced Cooling: Iron-shell outperforms epoxy
Field-Ready: Withstands rigorous transport