Cylinder Type
HFRS 105kV/3150kVA Modular Resonant Test System
Designed for adaptable high-voltage testing, the HFRS 105kV/3150kVA system offers unparalleled configuration flexibility with four independently operable modules featuring precision 22.5H±2% inductance and ≤1% linearity.
Multi-Configuration Capabilities
1. Single Module Operation
Output: 105kV at 30A (3.15MVA)
Insulation: 115kV/1min (40kV base-earth)
Ideal For: Compact field testing
2. Series Connection (4 Modules)
Output: 420kV at 30A (12.6MVA)
Withstand: 126kV/1min per module
3. Parallel Connection (4 Modules)
Output: 105kV at 120A (12.6MVA)
Current Capacity: 4× rated current
Precision Engineering
Parameter | Specification |
---|---|
Inductance Accuracy | 22.5H ±2% (≤1% linearity) |
Frequency Range | 20-300Hz (24.7Hz resonant) |
Quality Factor | Q≥120 @ 24.7Hz |
Thermal Limits |
|
Military-Grade Construction
Modular Design Advantages
Four identical modules enable:
Individual operation
Any combination series/parallel
Redundant backup capability
Iron-core segmented air gap with:
Class 1 copper windings
≤1% inductance linearity
Enhanced Cooling System
Iron-shell oil tanks provide:
40% better cooling than epoxy
Integrated cooling fins
Breather capsules feature:
Moisture indicators
Pressure relief valves
Certification & Compliance
Meets IEC 60060-1 (HV testing)
Oil standards per IEC 60296
Transport certified per IEC 61373
Key Benefits
Configuration Flexibility: 420kV series or 120A parallel
Precision Inductance: 22.5H±2% with ≤1% linearity
High Efficiency: Q≥120 at resonant frequency