600kV ~ 800kV Range
LQHVF 800kV/3000pF Wide-Frequency Capacitive Voltage Divider
Engineered for precision high-voltage testing across power systems, this 50-120Hz capacitive divider delivers laboratory-grade accuracy in field environments. With 3000:1 ratio and modular design, it's ideal for generator testing, cable validation, and renewable energy applications.
Core Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 800kV | IEC 60060-1 |
Frequency Range | 50-120Hz | IEC 60076-16 |
Capacitance | 3000pF | IEC 60358 |
Dividing Ratio | 3000:1 | - |
Measurement Accuracy | ≤±1% | IEC 60060-2 |
Dielectric Loss | <0.2% | IEC 60247 |
Insulation Withstand | 880kV for 60s | IEEE 4 |
Cooling System | ONAN (Oil Natural Air Natural) | IEC 60502 |
Frequency Response Performance
Maintains <0.8% ratio error across 50-120Hz range at 800kV
Advanced Engineering Features
Modular Connection System
Single-stage and two-stage serial measurement
Scalable corona-free HV connections
Special lead-wire for variable frequency power sources
Harmonic distortion immunity (up to 15th order)
Optimized Thermal Management
ONAN cooling maintains oil temperature <55°C
Natural convection for zero maintenance operation
Thermal stability across operating frequency range
Structural Design Advantages
Field-Optimized Components
Aluminum Corona Rings: Detachable design for compact transport
Removable Pedestal: Provides stability on uneven terrain
Scalable HV Bushings: Corona-free up to 880kV
Compact Connection Points: Tool-free assembly
Performance Validation
Test | Condition | Result |
---|---|---|
Frequency Response | 50-120Hz @ 800kV | ±0.75% max deviation |
Thermal Stability | 60 mins @ 800kV | Oil ΔT <30K |
Dielectric Withstand | 880kV for 60s | No flashover/corona |
Transport Simulation | IEC 60068-2-27 | Zero calibration shift |
Industry Applications
Generator Testing
60-120Hz withstand testing for turbine generators
HVDC Cable Validation
50-120Hz resonant testing on XLPE cables
Renewable Integration
Wind farm step-up transformer commissioning
Research Laboratories
Frequency-dependent dielectric studies
Operational Advantages
Field Deployment Efficiency
Rapid Configuration: 30-minute setup by 2 technicians
All-Weather Operation: -25°C to +50°C range
No External Power: Passive ONAN cooling system
Minimal Maintenance: Sealed oil-immersed design
Compliance & Certifications
IEC 60060-1/2: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 60502: Power cable accessories
IEC 60076: Power transformers
Field Operation Tip
For frequencies above 100Hz, reduce test duration to 30 minutes to maintain optimal dielectric stability and measurement accuracy.
Ordering Information
Package includes: Capacitive divider unit, aluminum corona rings, removable pedestal, VF-compatible measuring leads, calibration certificate. Optional: Frequency response report, transport cradle, and field verification kit.