600kV ~ 800kV Range
LQHVF 800kV/1000pF Dual-Stage Capacitive Voltage Divider
Engineered for precision high-voltage measurement in critical power infrastructure, this oil-immersed capacitive divider delivers laboratory-grade accuracy with field-deployable modularity. Featuring 4000:1 ratio certification and whole-system PD testing capability, it's ideal for substation commissioning and high-voltage research.
Core Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 800kV | IEC 60060-1 |
Configuration | 2-stage series | - |
Nominal Capacitance | 1000pF | IEC 60358 |
Dividing Ratio | 4000:1 | NIST Traceable |
Measurement Uncertainty | <1% | IEC 60060-2 |
Dielectric Loss | <0.2% | IEC 60247 |
Continuous Operation | 60 mins @ 800kV | IEEE 4 |
Partial Discharge | Whole-system measured | IEC 60270 |
Insulation Withstand | 880kV for 60s | IEC 62271 |
Cooling System | Oil-immersed (ONAN) | IEC 60502 |
Innovative Structural Design
Modular Removable Components
Corona Rings: Detachable aluminum alloy
LV Arm: Precision signal output module
HV Arm: 800kV rated with scalable connections
Removable Base: Quick assembly/disassembly
Oil-Immersed Technology
Enhanced dielectric strength
Thermal stability during extended operation
Contaminant protection for field use
Self-healing properties
Precision Measurement System
High-Accuracy Instrumentation
4000:1 ratio with NIST-traceable calibration
<1% measurement uncertainty (RMS)
Automatic temperature compensation
Harmonic distortion immunity up to 1.5% THD
Performance Validation
Test | Condition | Result |
---|---|---|
Thermal Endurance | 60 mins @ 800kV | Oil ΔT <28K |
Ratio Linearity | 200-800kV range | ±0.9% deviation |
Partial Discharge | Full system @ 800kV | <5pC sustained |
Dielectric Withstand | 880kV for 60s | No flashover/corona |
Industry Applications
Substation Commissioning
800kV GIS testing with 4000:1 precision
Cable System Validation
Partial discharge mapping on XLPE cables
Transformer Testing
Dielectric loss measurement at 800kV
High-Voltage Research
Component stress testing with precision metrics
Operational Advantages
Field Deployment Efficiency
Rapid Assembly: Modular components install in <45 minutes
Transport Optimization: Disassembled footprint 60% smaller
No Special Tools: Bolt-free connection system
All-Weather Operation: -25°C to +50°C temperature range
Compliance & Certification
IEC 60060-1/2: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 60137: Insulated bushings
NIST-traceable ratio calibration (4000:1)
Field Operation Tip
For PD measurements, ground all unused components and maintain 5-meter clearance from grounded objects to preserve <5pC sensitivity during whole-system tests.
Ordering Information
Package includes: HV/LV arms, removable base, aluminum corona rings, calibration certificate, and operation manual. Optional: Transport cases, field calibration kit, and PD measurement adapter.