600kV ~ 800kV Range
LQHVF 750kV/2000pF Coupling Capacitor & Capacitive Voltage Divider
Setting new industry standards in high-voltage technology, the LQHVF 750kV/2000pF system delivers unprecedented partial discharge performance with laboratory-verified<2pc at="" 750kv.="" this="" dual-function="" solution="" combines="" precision="" measurement="" and="" power="" line="" communication="" capabilities="" in="" a="" single="">
Technical Specifications
Electrical Parameters
Rated Voltage: 750kV AC
Capacitance: 2000pF ±3%
Frequency: 50Hz
Dividing Ratio: 2000:1 nominal
Performance Metrics
Accuracy: ≤±1% full scale
Dielectric Loss: <0.2%
Partial Discharge: <2pC at 750kV
Insulation Withstand: 825kV (110%) for 1min
Cooling System: ONAN (Oil Natural Air Natural)
Revolutionary Partial Discharge Performance
Industry Benchmark
15-20pC at 750kV
LQHVF Performance
<2pC at 750kV
PD measurements certified per IEC 60270 using calibrated ultra-high sensitivity detectors
Advanced Engineering Design
Breakthrough Insulation System
Multi-layer polypropylene-film dielectric
N2-inerted oil preservation (O₂ <0.3%)
Triple-shielded electrode design
Transport-Optimized Components
Quick-release aluminum corona rings
Modular HV arm disassembly
Compact shipping configuration (40% space reduction)
Precision Measurement Capabilities
Configuration Flexibility
Single-stage operation (0-375kV)
Two-stage series connection (0-750kV)
2000:1 precision ratio
Advanced Connection Technology
Corona-free HV terminals (RIV <15dB)
Variable frequency source integration (30-500Hz)
Low-inductance measuring leads (≤2nH/m)
Safety & Reliability Systems
Structural Integrity
Removable seismic-rated pedestal (IEC 60068-3)
Interlocking stability mechanism
Zero discharge at 825kV withstand test
Monitoring Systems
Real-time PD monitoring (IEC 60270 compliant)
Automatic de-energization on anomaly detection
Oil quality sensors with predictive analytics
Certifications & Industry Applications
International Standards
IEC 60060-1: High-voltage testing
IEC 60270: Partial discharge measurement
IEEE 4: Measurement standards
IEC 60358: Coupling capacitors
Critical Applications
Ultra-high-voltage transformer diagnostics
GIS partial discharge mapping
HVDC converter station monitoring
Smart grid sensor calibration
Operational Guidelines
Pre-test insulation verification (>15GΩ)
Dual-grounding confirmation (IEC 61936)
Cooling system activation 30 min pre-operation
Continuous PD monitoring during tests
Bi-annual dielectric strength validation
Safety Notice: Requires Class E4 PPE per IEC 61482. Minimum clearance: 8 meters for 750kV operations.
Innovation Spotlight: Achieving <2pC PD
Our proprietary dielectric technology enables breakthrough PD performance through:
Nanocomposite electrode coatings
Electrostatic field optimization
Vacuum-impregnated insulation
Triple-barrier corona suppression