600kV ~ 800kV Range
LQHVF 750kV/1500pF Coupling Capacitor & Capacitive Voltage Divider
Engineered for ultra-high-voltage precision, the LQHVF 750kV/1500pF system delivers industry-leading partial discharge performance and measurement accuracy. Featuring breakthrough PD levels as low as 2pC at 440kV and a precision 3000:1 ratio, this dual-function solution enables laboratory-grade performance in substation monitoring and high-voltage testing applications.
Technical Specifications
Electrical Parameters
Rated Voltage: 750kV AC
Capacitance: 1500pF ±4%
Frequency: 50Hz
Dividing Ratio: 3000:1 nominal
Performance Metrics
Accuracy: ≤±1% full scale
Dielectric Loss: <0.2%
Insulation Withstand: 825kV (110%) for 1min
Cooling System: ONAN (Oil Natural Air Natural)
Breakthrough Partial Discharge Performance
Voltage Level | Maximum PD | Industry Benchmark |
---|---|---|
440kV (58.7% Un) | <2pC | 5-8pC |
750kV (100% Un) | <10pC | 15-20pC |
PD measurements comply with IEC 60270 using calibrated detection systems
Advanced Engineering Design
Transport-Optimized System
Quick-release aluminum corona rings
Modular HV arm disassembly
N2-inerted oil preservation (O₂ <0.5%)
Compact shipping dimensions
Precision Measurement System
3000:1 high-sensitivity ratio
Low-noise output (SNR >68dB)
Temperature-compensated electronics
Versatile Connection System
Measurement Configurations
Single-stage operation (0-375kV)
Two-stage series connection (0-750kV)
Corona-free HV terminals (RIV <18dB)
Signal Integration
Variable frequency power source compatibility
Low-inductance measuring leads (≤2.5nH/m)
Scalable connectors for GIS/bushing interfaces
Stability & Safety Systems
Pedestal Design
Removable seismic-rated base (IEC 60068-3)
Interlocking stability mechanism
Ground-level measurement terminals
Dielectric Protection
Zero discharge at 825kV withstand test
Real-time PD monitoring system
Automatic de-energization on anomaly
Certifications & Industry Applications
International Standards
IEC 60060-1: High-voltage testing
IEC 60270: Partial discharge measurement
IEEE 4: Measurement standards
IEC 60358: Coupling capacitors
Critical Applications
Ultra-high-voltage transformer testing
Substation power line carrier communication
High-sensitivity partial discharge detection
HVDC converter station monitoring
Operational Guidelines
Pre-test insulation verification (>12GΩ)
Dual-grounding confirmation (IEC 61936)
Cooling system activation 30 min pre-operation
Continuous PD monitoring during tests
Annual dielectric strength validation
Safety Notice: Requires Class E4 PPE per IEC 61482. Minimum clearance: 8 meters for 750kV operations.