High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

600kV ~ 800kV Range

LQHVF 700kV/300pF High Voltage Divider & Coupling Capacitor | Precision Measurement Solution

Dual-purpose LQHVF 700kV/300pF capacitor voltage divider & coupling capacitor with ≤1% accuracy, <0.2% dielectric loss, and <5pC PD. Features removable oil-immersed design.


  • US$ 12,892.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

       

LQHVF 700kV/300pF Capacitor Voltage Divider & Coupling Capacitor

Engineered for dual-function precision in high-voltage environments, the LQHVF 700kV/300pF system serves as both a measurement-grade voltage divider and power line coupling capacitor. Designed for substation monitoring, HV laboratory testing, and grid communication systems, this oil-immersed solution delivers exceptional stability at 50Hz operations.

Technical Specifications

Electrical Parameters

  • Rated Voltage: 700kV AC

  • Nominal Capacitance: 300pF ±5%

  • Frequency: 50Hz (60Hz optional)

  • Dividing Ratio: 2000:1 nominal

Performance Metrics

  • Measurement Accuracy: ≤±1%

  • Dielectric Loss (tanδ): <0.2%

  • Partial Discharge: <5pC at 700kV

  • Continuous Operation: 60 min at 100% rating

Innovative Structural Design

Modular Oil-Immersed System

  • Removable corona rings (aluminum alloy)

  • Field-separable HV/LV arms

  • Baseplate with seismic anchors (IEC 60068-3)

  • N2-inerted tank (oxygen <0.5%)

Thermal Management

  • ONAN cooling (Oil Natural Air Natural)

  • Temperature stability: ±2°C at full load

  • Built-in oil quality sensors

Dual-Function Operation

FunctionCapabilityApplication
Voltage DividerPrecision RMS measurementTransformer testing, grid monitoring
Coupling CapacitorPLC signal injectionSubstation communication

Connection System

  • Corona-free HV terminals (RIV <35dB)

  • Calibrated measuring lead (50m standard)

  • Variable frequency source compatibility

Certifications & Industry Applications

International Standards

  • IEC 60358: Coupling capacitors

  • IEC 60060-1: HV test techniques

  • IEEE 4: Measurement standards

Critical Applications

  • EHV substation voltage monitoring

  • Power line carrier communication

  • Dielectric loss angle testing

  • Protective relay calibration

Safety & Maintenance Protocols

  1. Pre-energization insulation resistance test (>10GΩ)

  2. Double-grounding verification (IEC 61936)

  3. Oil dielectric strength monitoring (>60kV/2.5mm)

  4. 5-year recertification cycle (IEC 60480)

Safety Notice: Requires Class E3 PPE per IEC 61482 for all operations. Minimum clearance: 6 meters.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message