High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

600kV ~ 800kV Range

LQHVF 700kV/2500pF Dual-Ratio HV Capacitor | 20-300Hz Wideband Measurement

Dual-ratio LQHVF 700kV/2500pF capacitor with 20-300Hz bandwidth, ≤1% accuracy, <0.3% dielectric loss, and transport-optimized removable design.


  • US$ 15,062.00
  • Lead time: 45 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

       

LQHVF 700kV/2500pF Coupling Capacitor & Capacitive Voltage Divider

Engineered for precision across diverse testing scenarios, the LQHVF 700kV/2500pF system combines dual-ratio voltage measurement and coupling functions in a single, field-configurable unit. Designed for resonant testing facilities, power grid monitoring, and HV laboratory applications, this wideband solution operates from 20-300Hz with laboratory-grade accuracy and robust thermal management.

Technical Specifications

Electrical Parameters

  • Rated Voltage: 700kV AC

  • System Capacitance: 2500pF ±5%

  • Stage Configuration: 2×350kV (5000pF per stage)

  • Frequency Range: 20-300Hz

Performance Metrics

  • Dividing Ratios: 1000:1 & 2000:1 selectable

  • Accuracy: ≤±1% full scale

  • Dielectric Loss: <0.3%

  • Partial Discharge: ≤5pC at 700kV

  • Insulation Withstand: 770kV (110%) for 1min

Advanced Engineering Design

Modular Transport System

  • Quick-release aluminum corona rings

  • Stage-separable construction (2×350kV units)

  • Compact shipping dimensions

  • N2-inerted oil preservation (O₂ <0.5%)

Thermal & Frequency Performance

  • ONAN cooling with ±2°C stability

  • Wideband capacitance stability (±2% 20-300Hz)

  • Low-inductance design (≤8nH)

Versatile Measurement System

ConfigurationVoltage RangeOptimal Ratio
Single-Stage0-350kV1000:1
Dual-Stage Series0-700kV2000:1

Connection System

  • Corona-free HV terminals (RIV <28dB)

  • Variable frequency source integration (20-300Hz)

  • Scalable connectors for GIS/bushing interfaces

  • Triple-shielded measuring leads

Stability & Safety Systems

Pedestal Design

  • Removable seismic-rated base (IEC 60068-3 Class 2)

  • Ground-level measurement terminals

  • Interlocking stability feet

Dielectric Protection

  • Zero discharge at 770kV withstand test

  • Automatic PD cutoff at >5pC

  • Real-time oil quality monitoring

Certifications & Industry Applications

International Standards

  • IEC 60060-1: High-voltage testing

  • IEC 60270: Partial discharge measurement

  • IEEE 4: Measurement techniques

  • IEC 60358: Coupling capacitors

Critical Applications

  • Resonant test systems for transformers

  • EHV cable partial discharge mapping

  • HVDC converter station diagnostics

  • Substation PLC communication

Operational Guidelines

  1. Pre-test frequency calibration (20-300Hz sweep)

  2. Dual-grounding verification (IEC 61936)

  3. Cooling system activation 30 minutes pre-energization

  4. Continuous dielectric loss monitoring

  5. Annual recertification per IEC 60480

Safety Notice: Requires Class E4 PPE per IEC 61482. Minimum clearance: 6.5 meters for 700kV operations.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message