Primary Switchgear Cabinet
LQPSC 0.4KV/600A Switchgear: Intelligent Power Management Platform
Integrated Power Control Solution
Designed for precision industrial power distribution, the LQPSC 0.4KV/600A Primary Switchgear Cabinet combines protection, control, and monitoring in one robust system. Featuring a unique AC contactor plus visible fracture disconnector design with 10,000-operation mechanical life, this IP20-rated solution delivers comprehensive over-current/over-voltage protection with remote/local operation capabilities for demanding industrial environments.
Core Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 0.4kV (400V ±10%) | IEC 60038 |
Rated Current | 600A continuous | IEC 60947-1 |
Operating Voltage | AC 200V ±15% | IEC 60255-5 |
Mechanical Life | 10,000 operations | IEC 62271-100 |
Protection Rating | IP20 (finger-safe) | IEC 60529 |
Control Functions | Local/Remote operation | IEC 61439-1 |
Advanced Protection System
Hybrid Contactor-Disconnector
Visible fracture disconnector with integrated AC contactor ensures physical isolation during maintenance while enabling rapid switching operations.
Multi-Tier Protection
Over-Current: Current relay with 0.5-10s adjustable trip delay
Over-Voltage: Voltage relay protection up to 690V AC
Fast Cut-Out: <20ms response to critical faults
Intelligent Control
Seamless transition between local (manual) and remote (SCADA) operation modes with status confirmation indicators.
Comprehensive Measurement System
Precision Instrumentation
Current transformers (CTs): Class 1 accuracy
Voltage transformers (VTs): 0.5% measurement precision
Digital meters: Voltage/current/power factor display
Visual Status Monitoring
LED indicators for power on/load status
Fault warning lamps with color coding
Local/remote mode indication
Control Interface
Emergency stop button with mechanical lock
Selector switch for operation modes
Test/reset functions for protection relays
Component Architecture
Component | Function | Specification |
---|---|---|
AC Contactor | Main circuit switching | 600A rating, 10kA breaking capacity |
Visible Disconnector | Physical isolation | Visible contact gap ≥15mm |
Current Transformers | Load monitoring | 600/5A, Class 1, 15VA |
Protection Relays | Over-current/voltage | Adjustable settings, 4-20mA output |
Control Relays | Logic operations | 8-pin, 10A contact rating |
Metering | Parameter display | LCD with min/max recording |
Industrial Applications
Manufacturing Automation
Motor control centers for production lines requiring precise overload protection and remote monitoring.
Energy Management
Substation power distribution with real-time load measurement and power quality monitoring.
Building Management
HVAC system control in commercial complexes with integrated safety disconnects.
Installation & Operation
Mounting Requirements
Indoor installation only (ambient: -5°C to +40°C)
Minimum clearances: 800mm front, 100mm sides
Vertical mounting tolerance ≤1°
Commissioning Procedure
Verify disconnector operation (open/close torque ≤50Nm)
Calibrate CTs/VTs at 25%, 50%, 100% load
Test protection relays with fault simulation
Maintenance Schedule
Frequency | Action |
---|---|
Monthly | Operate disconnector 5x (min) |
Quarterly | Clean contacts, check indicators |
Annually | Full relay calibration, torque checks |
Technical Advantages
Feature | Benefit |
---|---|
Hybrid Contactor-Disconnector | Combines switching speed with visible isolation safety |
Multi-Layer Protection | Prevents equipment damage from 5 fault types |
Dual Control Modes | Flexible operation for normal/emergency scenarios |
Comprehensive Instrumentation | Real-time monitoring reduces diagnostic time by 60% |