High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Primary Switchgear Cabinet

LQPSC 400V/187A Primary Switchgear Cabinet: Heavy-Current Power Distribution Solution

Technical specifications of LQPSC 0.4KV/1875A primary switchgear cabinet with 25kA short-circuit protection, IP20 rating, and advanced monitoring instruments for industrial power systems.


  • US$ 4,406.00
  • Lead time: 40 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQPSC 0.4KV/1875A Primary Switchgear Cabinet

High-capacity power distribution solution designed for industrial applications requiring 1875A current handling with 25kA short-circuit protection and comprehensive monitoring capabilities.

Technical Specifications

  • Model: LQPSC 0.4KV/1875A

  • Rated Frequency: 50Hz

  • Rated Voltage: 0.4kV (400V AC)

  • Rated Current: 1875A

  • Short-Time Current: 25kA

  • Protection Rating: IP20 (finger-safe design)

  • Operation Time Delay: 5s

  • Control Voltage: 220V AC (switching operations)

  • Mechanical Endurance: 10,000 operations

  • Installation: Indoor use

Control Panel Features

  • Monitoring Instruments:

    • Voltmeter for phase-to-phase voltage measurement

    • Ammeter for current load monitoring

  • Visual Indicators:

    • Power supply switch-on indicator lamp

    • Power supply switch-off indicator lamp

  • Control Functions:

    • Remote function selector switch

    • Local/remote operation mode

Core Functional Capabilities

  • High-Current Distribution: 1875A continuous rating

  • Short-Circuit Protection: 25kA withstand capacity

  • Delayed Operation: 5-second time delay for protection coordination

  • Dual Control Modes: Local and remote operation

  • Real-Time Monitoring: Voltage and current measurement

Protection System Details

ParameterSpecification
Short-Circuit Withstand25kA for 1 second
Overload Capacity150% of rated current for 30 seconds
Protection Coordination5-second adjustable time delay
Arc ContainmentInternal arc classification: IAC AFLR

Industrial Applications

  • Steel manufacturing power distribution

  • Industrial plant main switchboards

  • Data center high-density power systems

  • Large-scale industrial motor control

  • Foundry and smelting operations

Design & Construction

  • Robust Enclosure: 3mm powder-coated steel

  • Thermal Management: Forced-air ventilation with filters

  • Busbar System: Tin-plated copper with 2500A rating

  • Component Layout: Segregated compartments for safety

  • Cable Management: Bottom entry with 4×200mm² cable capacity

Installation Requirements

  • Mounting: Floor-standing with M20 anchor bolts

  • Clearances:

    • Front: 1200mm minimum

    • Rear: 500mm minimum

    • Sides: 300mm minimum

  • Environmental Conditions:

    • Temperature: 0°C to +45°C

    • Humidity: ≤90% RH (non-condensing)

    • Altitude: ≤2000m ASL

  • Power Connections: 4× 500mm² per phase

Maintenance Protocol

  1. Monthly:

    • Visual inspection of instruments and lamps

    • Verify control voltage stability

  2. Quarterly:

    • Calibration check of meters

    • Busbar connection torque verification

  3. Biannual:

    • Insulation resistance test (min 1MΩ)

    • Time delay function verification

  4. Annual:

    • Full protection relay testing

    • Contact resistance measurement

Compliance Standards

  • IEC 61439-1: Low-voltage switchgear assemblies

  • IEC 62271-200: AC metal-enclosed switchgear

  • IEC 60529: IP degree of protection

  • IEEE C37.20: Switchgear standards

Certified for industrial power distribution in high-current applications.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message