Primary Switchgear Cabinet

LQPSC 0.4KV/4000A Primary Switchgear Cabinet: Heavy-Current Three-Phase Protection System

Technical specifications of LQPSC 0.4KV/4000A three-phase primary switchgear cabinet with 1250A tripping current and 1.1x rated current protection for transformer applications.


  • US$ 4,918.00
  • Lead time: 40 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQPSC 0.4KV/4000A Primary Switchgear Cabinet

Heavy-current protection solution for 400V LV transformer inputs featuring 4500A testing capacity and intelligent 1.1× rated current protection principle.

Core Technical Specifications

  • Model: LQPSC 0.4KV/4000A

  • Phase Configuration: Three-phase

  • System Voltage: 380V AC

  • Rated Current (400V Side): 4000A

  • Per-Phase Current: 1000A

  • Tripping Current: 1250A

  • Testing Transformer Current: ≥4500A

  • Tripping Off Current: 1500A

  • Protection Principle: 1.1× rated current

Primary Application

Protection and control of 400V LV side input for regulator front pole installations in power distribution systems.

Protection System Design

Current Settings & Coordination

ComponentRated CurrentMax Operating CurrentTripping Current
Main Transformer Switch4000A4500A1500A
LV Busbar Subdevice1000A (configurable)1250A1250A

Protection Philosophy

  • 1.1× Rated Current Principle:

    • Primary protection setting for transformer circuits

    • Prevents overcurrent during voltage regulator adjustments

    • Mitigates station transformer overload risks

  • User-Adjustable Settings:

    • Configurable trip values based on actual load profiles

    • Customizable protection thresholds for specific applications

System Architecture

  • Main Circuit Protection:

    • Three-phase circuit breaker (4000A rating)

    • 4500A testing capacity for transformer inputs

    • 1500A tripping capacity for fault isolation

  • Secondary Loop Protection:

    • LV busbar subdevices (1000A configurable rating)

    • 1250A maximum operating current capacity

    • Integrated current-limiting protection

  • Coordination Logic:

    • Selective tripping hierarchy

    • Time-current coordination

    • Load-dependent protection settings

Protection Scenarios

Fault ConditionProtection ResponseResponse Time
Transformer Overcurrent (1.1× In)Warning indication with delayed tripAdjustable 5-60s
Severe Overload (1.25-1.5× In)Instantaneous trip of affected circuit<100ms
Short CircuitMain circuit isolation with arc suppression<50ms
Voltage Regulator MalfunctionSecondary loop disconnection<500ms

Industrial Applications

  • Power substation LV distribution

  • Transformer station input protection

  • Industrial plant main switchgear

  • Voltage regulator front-end protection

  • Heavy-current manufacturing facilities

Design Features

  • Intelligent Protection: Adaptive 1.1× current principle with manual override

  • High-Current Capacity: 4000A main bus with 4500A testing capability

  • Modular Design: Configurable subdevices for secondary loops

  • Visual Indicators:

    • Load status indicators

    • Protection activation signals

    • System health monitoring

  • Safety Interlocks:

    • Preventive blocking during maintenance

    • Voltage presence indicators

    • Key-operated control transfer

Installation Requirements

ParameterSpecification
MountingFloor-standing with vibration isolation
ClearancesFront: 1500mm, Rear: 800mm, Sides: 500mm
Ambient Temperature0°C to +40°C
Relative Humidity≤90% RH (non-condensing)
Power Connections4×500mm² per phase minimum

Protection Configuration Protocol

  1. Determine transformer rated current (In)

  2. Set protection threshold at 1.1× In

  3. Configure LV subdevices at 1000A base rating

  4. Set maximum operating current at 1250A (1.25×)

  5. Calibrate tripping mechanism at 1250A

  6. Verify coordination with upstream devices

  7. Implement user-specific adjustments as needed

Compliance Standards

  • IEC 61439-1: Low-voltage switchgear assemblies

  • IEC 60255: Electrical relays

  • IEC 60947-2: Circuit-breakers

  • IEEE C37.20: Switchgear standards

  • ANSI/IEEE C37.13: Low-voltage AC power circuit breakers

Designed for critical transformer protection applications with configurable protection parameters.