Primary Switchgear Cabinet
LQPSC 0.4KV/750A Primary Switchgear Cabinet
Industrial-grade single-phase power distribution solution featuring exceptional 200,000-operation durability and robust short-circuit protection.
Technical Specifications
Model: LQPSC 0.4KV/750A
Phase Configuration: Single-phase
Rated Voltage: 0.4kV (400V AC)
Rated Current: 750A
Frequency: 50Hz
Short-Circuit Rating: 8kA
Control Voltage: AC220V (switching operations)
Mechanical Endurance: 200,000 operations
Installation: Indoor use only
Key Features: Isolation switch, switch-on indicator lamp
Core Functional Capabilities
High-Current Distribution: 750A continuous rating for demanding loads
Visual Status Monitoring: Integrated switch-on indicator lamp
Safety Isolation: Physical disconnection capability
Remote Control: Switch-on/off via 220V control signals
Fault Protection: 8kA short-circuit withstand capability
Durability & Reliability Features
Extended Mechanical Life: 200,000 operations (4× industry standard)
Robust Contact System: Silver-alloy contacts for reduced erosion
Thermal Management: Optimized heat dissipation design
Vibration Resistance: Reinforced structural integrity
Corrosion Protection: Zinc-coated steel construction
Industrial Applications
Heavy manufacturing power distribution
Industrial furnace power control
Large-scale HVAC systems
Foundry and metal processing equipment
Industrial pump station control
Protection System Details
Protection Type | Specification |
---|---|
Short-Circuit Withstand | 8kA for 1 second |
Isolation Safety | Visible contact separation (≥10mm gap) |
Overload Capacity | 125% of rated current for 1 hour |
Indicator System | Dual-color status lamp (red/green) |
Installation Requirements
Mounting: Floor-standing with M16 anchor bolts
Clearances:
Front: 1000mm minimum
Rear: 300mm minimum
Environmental Conditions:
Temperature: -5°C to +40°C
Humidity: ≤95% RH (non-condensing)
Altitude: ≤2000m ASL
Cable Connections: 2× 400mm² per phase
Maintenance Protocol
Monthly:
Visual inspection of indicator lamps
Verify switch operation smoothness
Quarterly:
Contact resistance measurement
Terminal torque verification
Annual:
Insulation resistance test (min 1MΩ)
Full operational sequence test
5-Year:
Contact replacement (if wear >50%)
Dielectric strength test (3.5kV AC)
Compliance Standards
IEC 61439-1: Low-voltage switchgear assemblies
IEC 60947-3: Switches, disconnectors and fuse-combination units
ISO 9001: Quality management systems
RoHS 3: Hazardous substance restriction
Certified for industrial power distribution in demanding environments.