High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Primary Switchgear Cabinet

LQPGL -0.4kV/630A Single-Phase Primary Switchgear Cabinet: Indoor Power Distribution Solution

Technical specifications of LQPGL -0.4kV/630A shielded primary switchgear cabinet with 16KA transient protection and remote operation capabilities for indoor installations.


  • US$ 3,698.00
  • Lead time: 40 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQPGL -0.4kV/630A Single-Phase Primary Switchgear Cabinet

Shielded indoor switchgear solution featuring 20,000-operation durability and comprehensive protection functions for critical power distribution applications.

Core Technical Specifications

  • Phase Configuration: Single-phase

  • Rated Frequency: 50Hz

  • Rated Voltage: 0.4kV (400V AC)

  • Rated Current: 630A

  • Transient Current Rating: 16kA

  • Control Voltage: AC220V (switching operations)

  • Mechanical Endurance: 20,000 operations

  • Installation Environment: Indoor use only

  • Enclosure: Electromagnetic shielded design

Primary Functions

  • Electrical Isolation: Physical circuit separation capability

  • Remote Operation: Switch-on/off via control signals

  • Protection Systems:

    • Over-voltage protection

    • Over-current protection

  • Measurement & Indication: Real-time electrical parameter monitoring

Key Components

  • Instrument Transformers:

    • Current transformers (CTs)

    • Voltage transformers (VTs)

  • Switching Devices:

    • AC contactors

    • Grounding switches

  • Protection Relays:

    • Current relays

    • Voltage relays

    • Intermediate (auxiliary) relays

  • Control Interface:

    • Operation buttons

    • Status indicator lamps

Shielded Enclosure Features

  • EMI/RFI electromagnetic shielding

  • Corrosion-resistant coated steel

  • Touch-safe design per IEC 61439

  • Ventilation with particulate filters

  • Grounding continuity assurance

Industrial Applications

  • Commercial building main distribution panels

  • Data center power distribution units

  • Laboratory critical power systems

  • Hospital electrical infrastructure

  • Indoor industrial substations

Installation Requirements

ParameterSpecification
Ambient Temperature+5°C to +40°C
Relative Humidity≤85% (non-condensing)
Altitude≤2000m ASL
Vibration Tolerance≤0.3g acceleration
Clearance Space800mm front access minimum

Protection Coordination

  • 16kA transient current withstand (3-cycle)

  • Over-voltage threshold: 110% of rated voltage

  • Over-current tripping: 125% of rated current

  • Ground fault detection: 10% imbalance sensitivity

  • Arc-flash mitigation design

Maintenance Protocol

  1. Monthly: Visual inspection of indicators and contacts

  2. Quarterly: Relay functional testing

  3. Biannual:

    • Contact resistance measurement

    • Shielding integrity verification

  4. Annual:

    • Dielectric strength test (2.5kV AC)

    • Protection relay calibration

Compliance Standards

  • IEC 61439: Low-voltage switchgear assemblies

  • IEC 62271: High-voltage switchgear standards

  • IEEE C37.20: Indoor switchgear requirements

  • EMC Directive 2014/30/EU

Certified for indoor electrical distribution in commercial and light industrial environments.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message