High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Primary Switchgear Cabinet

LQPSC 0.22KV/1250A Primary Switchgear Cabinet: High-Current Single-Phase Distribution Solution

Technical specifications of LQPSC 0.22KV/1250A primary switchgear cabinet with 100,000-operation durability, insulation knife-switch, and IP20 protection for industrial applications.


  • US$ 3,962.00
  • Lead time: 40 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQPSC 0.22KV/1250A Primary Switchgear Cabinet

Industrial-grade single-phase power distribution solution featuring exceptional 100,000-operation durability and safe insulation knife-switch for maintenance operations.

Technical Specifications

  • Model: LQPSC 0.22KV/1250A

  • Phase Configuration: Single-phase

  • Rated Frequency: 60Hz

  • Rated Voltage: 0.22kV (220V AC)

  • Rated Current: 1250A

  • Control Voltage: AC220V (switching operations)

  • Protection Rating: IP20 (finger-safe design)

  • Mechanical Endurance: 100,000 operations

  • Key Component: Insulation knife-switch disconnector

  • Installation: Indoor use only

Core Functional Features

  • High-Current Distribution: 1250A continuous rating

  • Safe Isolation: Insulation knife-switch for visible circuit disconnection

  • Remote Control: Switch-on/off via 220V control signals

  • Durability: 100,000 mechanical operations (3× industry standard)

  • Protection: IP20 rating prevents finger contact with live parts

Insulation Knife-Switch Advantages

FeatureBenefit
Visible BreakClear physical isolation confirmation
Insulated BladesEnhanced safety during operation
Quick-Make/Quick-BreakRapid switching operation
Maintenance-FriendlyEasy access for inspection and service

Design & Construction

  • Robust Enclosure: 2.5mm galvanized steel construction

  • Thermal Management: Natural convection cooling design

  • Busbar System: Silver-plated copper with 1500A rating

  • Component Layout: Segregated compartments for safety

  • Isolation Verification: Clear visual gap indication

Industrial Applications

  • Industrial manufacturing power distribution

  • Large commercial building main switchboards

  • Data center power distribution units

  • Water treatment plant electrical systems

  • Industrial process control centers

Safety Mechanisms

  • Visible Disconnection: Clear isolation gap ≥15mm

  • Interlock System: Prevents switch operation when closed

  • Arc Containment: Designed to channel arc gases safely

  • Grounding: Integrated grounding contacts

Installation Requirements

  • Mounting: Floor-standing with M16 anchor bolts

  • Clearances:

    • Front: 1000mm minimum

    • Rear: 400mm minimum

  • Environmental Conditions:

    • Temperature: -5°C to +40°C

    • Humidity: ≤85% RH (non-condensing)

    • Altitude: ≤2000m ASL

  • Power Connections: 2× 300mm² per phase minimum

Operation & Maintenance

Switching Procedure

  1. Verify load is within safe parameters

  2. Ensure proper isolation using knife-switch

  3. Engage remote control system

  4. Monitor operation via status indicators

Maintenance Schedule

  • Monthly:

    • Visual inspection of knife-switch contacts

    • Verify smooth operation mechanism

  • Quarterly:

    • Contact resistance measurement

    • Insulation resistance test (min 1MΩ)

  • Annual:

    • Full operational sequence test

    • Control circuit verification

  • Every 50,000 Operations:

    • Contact replacement

    • Mechanism lubrication

Compliance Standards

  • IEC 60947-3: Switches, disconnectors and fuse-combination units

  • IEC 61439-1: Low-voltage switchgear assemblies

  • IEC 60529: IP degree of protection

  • IEEE C37.20: Switchgear standards

Certified for industrial power distribution with safety isolation capabilities.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message