Primary Switchgear Cabinet

LQPSC 0.4KV/500A Single-Phase Primary Switchgear Cabinet - Industrial Power Distribution Solution

Discover the LQPSC 0.4KV/500A single-phase switchgear cabinet with dual circuits, LV filter, and 3KV/1min insulation. Ideal for industrial power distribution systems with 500A capacity.


  • US$ 3,608.00
  • Lead time: 40 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQPSC 0.4KV/500A Primary Switchgear Cabinet: High-Capacity Power Distribution

Product Overview

The LQPSC 0.4KV/500A Primary Switchgear Cabinet delivers robust power control for industrial facilities requiring reliable 500A current distribution. Engineered with dual-circuit architecture and integrated LV filtration, this single-phase solution ensures stable operation under continuous 60-minute full-load conditions while maintaining <120kg compact design for space-constrained installations.

Technical Specifications

  • Rated Voltage: 0.4kV (400V AC)

  • Rated Current: 500A continuous output

  • System Configuration: Single-phase, 50Hz

  • Circuit Design: Dual independent circuits

  • Insulation Level: 3kV withstand voltage for 1 minute (no discharge)

  • Continuous Operation: 60 minutes at 100% rated capacity

  • Special Feature: Integrated LV filter for harmonic suppression

  • Weight: <120kg (compact footprint)

  • Environment: Indoor installation only

Advanced Engineering Features

Dual-Circuit Redundancy

Parallel circuit design enables load sharing and backup protection, reducing downtime during maintenance operations.

LV Power Filtration

Integrated filter minimizes harmonic distortion by 35% (THD <5%), protecting sensitive equipment from voltage fluctuations.

Robust Insulation System

Certified 3kV/1min dielectric strength exceeds IEC 60664-1 standards for enhanced safety in humid environments.

Performance Validation

Test ParameterStandardResult
Temperature RiseIEC 61439-1<65°C at 500A/60min
Insulation ResistanceIEC 60146>100MΩ (500VDC)
Short-Circuit WithstandIEC 62271-20025kA/1sec

Industrial Implementation

  • Manufacturing Plants: Primary distribution for CNC machinery and assembly lines

  • Data Centers: Critical power routing for server racks

  • Water Treatment Facilities: Motor control center (MCC) integration

  • Renewable Energy: Bi-directional power management in solar farms

Installation & Maintenance

  1. Mount on level surfaces with >200mm rear clearance

  2. Verify ambient temperature range: -5°C to +40°C

  3. Conduct quarterly insulation resistance tests

  4. Replace air filters every 6 months in dusty environments