Primary Switchgear Cabinet
LQPSC 0.4KV/500A Primary Switchgear: Dual-Circuit Power Distribution Solution
Engineered for High-Density Power Control
This single-phase switchgear cabinet delivers 500A power distribution through dual independent circuits within an ultra-compact <120kg enclosure. Designed for industrial facilities requiring reliable power routing with harmonic mitigation, the integrated LV filter ensures stable operation even during 60-minute continuous full-load conditions.
Core Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 0.4kV (400V ±10%) | IEC 60038 |
Rated Current | 500A continuous per circuit | IEC 60947 |
Insulation Level | 3kV/1min (no discharge) | IEC 60664-1 |
Continuous Operation | 60min @ 100% load | IEC 61439-1 |
Weight | <120kg | - |
Dimensions | Optimized for tight spaces | - |
Advanced Power Management Features
Dual-Circuit Architecture
Parallel 500A circuits enable load sharing and redundant operation, reducing downtime during maintenance by 45% compared to single-circuit designs.
Integrated LV Harmonic Filter
Suppresses voltage distortion to <5% THD, protecting sensitive equipment from harmonic damage while improving power factor by 0.95.
Robust Insulation System
3kV/1min dielectric strength exceeds standard requirements, ensuring safe operation in humid industrial environments (up to 95% RH).
Performance Validation Data
Temperature Stability: Max 65°C rise at 500A/60min (IEC 61439-1 verified)
Harmonic Mitigation: 35% reduction in 5th/7th harmonics with LV filter
Mechanical Endurance: 10,000+ operation cycles (IEC 62271-100)
Short-Circuit Protection: 25kA/1sec withstand capacity (optional)
Industrial Implementation Scenarios
Manufacturing Plants
Power distribution for CNC clusters and robotic assembly lines where harmonic-sensitive drives require clean power.
Commercial Facilities
Centralized power control in shopping malls/hospitals with space-constrained electrical rooms.
Renewable Energy
Grid interconnection point for solar inverters requiring harmonic filtration.
Installation & Maintenance Protocol
Mounting: Install on level surfaces with ≥200mm rear clearance
Commissioning:
Verify insulation resistance >100MΩ at 500VDC
Test harmonic filter at 25%, 50%, 100% load
Routine Maintenance:
Quarterly thermographic scans of busbars
Biannual filter element inspection
Annual dielectric strength verification
Technical Advantages Summary
Feature | Benefit | Value Impact |
---|---|---|
Dual 500A Circuits | Load balancing & redundancy | ↑ System uptime 30% |
Integrated LV Filter | Harmonic suppression | ↓ Equipment failure 45% |
<120kg Compact Design | Space optimization | ↓ Installation area 40% |