100kVA ~ 200kVA Range
LQLVF 200kVA/500A Power Noise Filter: High-Current EMI Suppression with ONAN Cooling
Extended Range Noise Attenuation
Engineered for comprehensive EMI suppression in industrial power systems:
10KHz-100KHz range: >40dB attenuation
100KHz-1000KHz range: >60dB attenuation
Enhanced low-frequency performance starting at 10kHz
Verified per IEC 61000-4-7 measurement standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 200kVA |
Voltage Rating | Input/Output: 0.4kV |
Current Rating | Input/Output: 500A |
Phase Configuration | Single Phase |
Frequency | 50Hz |
Cooling System | ONAN (Oil Natural Air Natural) |
Insulation Level | 3kV/1min withstand |
Advanced ONAN Cooling Technology
Optimized thermal management for high-current applications:
Mineral oil insulation with natural convection cooling
Temperature rise limit: 65°C at full load
Designed for ambient temperatures up to 45°C
Expansion tank with nitrogen cushion
Optimized radiator fins for efficient heat dissipation
High-Current Capability
Robust design for industrial power applications:
500A continuous current rating
Low-loss design (efficiency >98% at full load)
Copper windings with 150% overload capacity
Short-circuit withstand: 25kA for 100ms
Dynamic response time <5ms for load variations
Enhanced Low-Frequency Performance
Specialized design for challenging EMI environments:
Effective attenuation starting at 10kHz
Harmonic resonance damping technology
Frequency-stable reactors (±1% across load range)
Core saturation protection during transients
Multi-stage filtering topology
Industrial Applications
Ideal for 0.4kV systems in:
Industrial motor control centers
Large-scale HVAC power systems
Plastic injection molding machinery
Industrial furnace control systems
Material handling conveyor systems
Pump and compressor stations
Installation & Maintenance Protocol
Ensure optimal performance with these guidelines:
Maintain minimum 500mm clearance for natural convection
Verify oil dielectric strength ≥40kV before commissioning
Use compression lugs rated for 600A connections
Torque power terminals to 60 N·m ±5%
Perform annual power factor/dissipation factor tests
Test insulation resistance annually (≥100MΩ at 2.5kV DC)
Monitor oil temperature during operation
Safety & Protection Systems
Engineered for reliable operation:
Pressure relief device with alarm contacts
Buchholz relay for gas detection
Dual RTD temperature sensors (oil and winding)
Surge protection (15kV/20μs withstand)
Automatic discharge circuit for capacitors
IP55-rated enclosure for harsh environments
Compliance & Standards
Meets international requirements including:
IEC 60076 power reactor standards
IEEE C57.12.00 liquid-immersed equipment
EN 50588-1 medium-power transformers
IEC 61000-3-12 harmonic emissions
ANSI/IEEE C57.91 thermal loading guide
For high-current applications or technical datasheets, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.