100kVA ~ 200kVA Range
LQLVF 100kVA/2*316.7A Power Noise Filter (Model LNF-190): ONAN Cooled HV EMI Suppression
Premium HV Noise Attenuation Performance
Model LNF-190 delivers critical EMI suppression for 3kV industrial power systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Filter reactor quality factor: >70
Dual-frequency compatibility (50-60Hz)
Verified per IEC 61000-4-7 measurement standards
Technical Specifications
Parameter | Specification |
---|---|
Model Number | LNF-190/2*316.7 |
Rated Capacity | 100kVA |
Rated Voltage | 3kV Input/Output |
Current Rating | 2 × 316.7A (633.4A total) |
Frequency Range | 50-60Hz |
Cooling System | ONAN (Oil Natural Air Natural) |
Insulation Level | 5kV/1min withstand |
Weight | 280kg |
Installation | Sub-stage switchgear cabinet |
Advanced ONAN Cooling Technology
Optimized thermal management for high-current HV applications:
Mineral oil insulation with natural convection cooling
Designed for 60°C average oil temperature rise
Temperature stabilization time: <10 minutes after startup
Sealed tank with nitrogen blanket protection
Optimized radiator fins for heat dissipation
High-Voltage Design Features
Engineered for reliable 3kV operation:
Enhanced creepage distance: ≥25mm/kV
Corona-free design up to 3.6kV operational voltage
Partial discharge inception voltage >4.5kV
Class H insulation system (180°C rating)
Bushing design per IEC 60137 standards
Switchgear Integration Design
Optimized for HV switchgear cabinet installations:
Compact dimensions for retrofitting existing compartments
Front-access terminals with safety shrouds
Vibration-dampened mounting system
HV cable entry points with silicone rubber grommets
Thermal alignment with switchgear airflow patterns
Industrial Applications
Ideal for 3kV systems in:
Industrial HV switchgear installations
Power generation substations
Mine power distribution centers
Marine propulsion power systems
Railway electrification systems
Large industrial motor drive systems
Dual-Circuit High-Current Design
Robust performance for demanding applications:
633.4A total current capacity (2×316.7A)
Low-loss design (efficiency >98% at full load)
Copper windings with 150% overload capacity
Dynamic response time <5ms for load variations
Short-circuit withstand: 25kA for 100ms
Installation & Maintenance Protocol
Ensure optimal performance in HV applications:
Verify cabinet clearance ≥500mm for natural convection
Use silicone-insulated HV cable (8kV rating minimum)
Check oil dielectric strength ≥45kV before commissioning
Torque HV terminals to 90 N·m ±5%
Perform annual power factor/dissipation factor tests
Test insulation resistance annually (≥1000MΩ at 5kV DC)
Monitor oil temperature during operation
Safety & Protection Systems
Engineered for reliable HV operation:
Pressure relief device with alarm contacts
Buchholz relay for gas detection
Dual RTD temperature sensors (oil and winding)
Surge protection (20kV/20μs withstand)
Automatic discharge circuit for capacitors
IP55-rated enclosure for harsh environments
Compliance & Standards
Meets international HV requirements:
IEC 62271-200 for AC metal-enclosed switchgear
IEEE C57.12.00 liquid-immersed equipment
EN 50522 earthing of power installations
IEC 60076 power reactor standards
IEC 61000-3-12 harmonic emissions
ANSI/IEEE C57.91 thermal loading guide
For Model LNF-190 technical documentation or custom HV solutions, contact our specialized engineering team. Performance validated per IEC 60270 partial discharge standards.