High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kVA ~ 200kVA Range

LQLVF 100kVA/2*316.7A Power Noise Filter | Model LNF-190 ONAN Cooled HV EMI Solution

Model LNF-190 HV noise filter with 316.7A rating, ONAN cooling, and 60dB attenuation. 5kV insulation for 3kV switchgear in 50-60Hz systems.


  • US$ 2,893.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF 100kVA/2*316.7A Power Noise Filter (Model LNF-190): ONAN Cooled HV EMI Suppression

Premium HV Noise Attenuation Performance

Model LNF-190 delivers critical EMI suppression for 3kV industrial power systems:

  • 40KHz-100KHz range: >40dB attenuation

  • 100KHz-1MHz range: >60dB attenuation

  • Filter reactor quality factor: >70

  • Dual-frequency compatibility (50-60Hz)

  • Verified per IEC 61000-4-7 measurement standards

Technical Specifications

ParameterSpecification
Model NumberLNF-190/2*316.7
Rated Capacity100kVA
Rated Voltage3kV Input/Output
Current Rating2 × 316.7A (633.4A total)
Frequency Range50-60Hz
Cooling SystemONAN (Oil Natural Air Natural)
Insulation Level5kV/1min withstand
Weight280kg
InstallationSub-stage switchgear cabinet

Advanced ONAN Cooling Technology

Optimized thermal management for high-current HV applications:

  • Mineral oil insulation with natural convection cooling

  • Designed for 60°C average oil temperature rise

  • Temperature stabilization time: <10 minutes after startup

  • Sealed tank with nitrogen blanket protection

  • Optimized radiator fins for heat dissipation

High-Voltage Design Features

Engineered for reliable 3kV operation:

  • Enhanced creepage distance: ≥25mm/kV

  • Corona-free design up to 3.6kV operational voltage

  • Partial discharge inception voltage >4.5kV

  • Class H insulation system (180°C rating)

  • Bushing design per IEC 60137 standards

Switchgear Integration Design

Optimized for HV switchgear cabinet installations:

  • Compact dimensions for retrofitting existing compartments

  • Front-access terminals with safety shrouds

  • Vibration-dampened mounting system

  • HV cable entry points with silicone rubber grommets

  • Thermal alignment with switchgear airflow patterns

Industrial Applications

Ideal for 3kV systems in:

  • Industrial HV switchgear installations

  • Power generation substations

  • Mine power distribution centers

  • Marine propulsion power systems

  • Railway electrification systems

  • Large industrial motor drive systems

Dual-Circuit High-Current Design

Robust performance for demanding applications:

  • 633.4A total current capacity (2×316.7A)

  • Low-loss design (efficiency >98% at full load)

  • Copper windings with 150% overload capacity

  • Dynamic response time <5ms for load variations

  • Short-circuit withstand: 25kA for 100ms

Installation & Maintenance Protocol

Ensure optimal performance in HV applications:

  1. Verify cabinet clearance ≥500mm for natural convection

  2. Use silicone-insulated HV cable (8kV rating minimum)

  3. Check oil dielectric strength ≥45kV before commissioning

  4. Torque HV terminals to 90 N·m ±5%

  5. Perform annual power factor/dissipation factor tests

  6. Test insulation resistance annually (≥1000MΩ at 5kV DC)

  7. Monitor oil temperature during operation

Safety & Protection Systems

Engineered for reliable HV operation:

  • Pressure relief device with alarm contacts

  • Buchholz relay for gas detection

  • Dual RTD temperature sensors (oil and winding)

  • Surge protection (20kV/20μs withstand)

  • Automatic discharge circuit for capacitors

  • IP55-rated enclosure for harsh environments

Compliance & Standards

Meets international HV requirements:

  • IEC 62271-200 for AC metal-enclosed switchgear

  • IEEE C57.12.00 liquid-immersed equipment

  • EN 50522 earthing of power installations

  • IEC 60076 power reactor standards

  • IEC 61000-3-12 harmonic emissions

  • ANSI/IEEE C57.91 thermal loading guide