LQLVF 150kVA/2X250A Power Noise Filter: Lightweight EMI Suppression for Switchgear Cabinets
High-Efficiency Noise Attenuation
Engineered for critical EMI suppression in 0.6kV power distribution systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Filter reactor quality factor: >70
Verified per IEC 61000-4-7 measurement standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 150kVA |
Voltage Rating | Input/Output: 0.6kV |
Current Rating | Input/Output: 250A (dual-circuit) |
Frequency | 50Hz |
Phase Configuration | Single Phase |
Insulation Level | 5kV/1min (no abnormal phenomena) |
Weight | <100kg (lightweight design) |
Lightweight Compact Design
Optimized for space-constrained LV switchgear cabinets:
Ultra-lightweight <100kg construction
Standard switchgear cabinet footprint
Front-access terminals for easy maintenance
Vibration-resistant mounting brackets
Thermal management optimized for enclosed spaces
Cable entry points compatible with 40mm knockouts
Advanced Filter Reactor Technology
High-performance components for superior EMI suppression:
Quality factor >70 for precise frequency targeting
Amorphous metal core for reduced weight
Low-loss design (efficiency >98%)
Thermal overload protection (140°C cutoff)
Vacuum impregnated windings for moisture resistance
Enhanced Insulation System
Robust electrical protection in compact form factor:
5kV/1min dielectric strength
Class F insulation system (155°C rating)
Creepage distance: ≥18mm/kV
Partial discharge inception voltage >3.2kV
Triple-coat epoxy encapsulation
Industrial Applications
Ideal for 0.6kV systems in:
LV switchgear cabinets
Manufacturing plant power distribution
Data center power distribution units
Renewable energy converter stations
Industrial motor control centers
Building management system power lines
Dual-Circuit Advantages
Operational flexibility and redundancy:
Independent 250A circuits for load balancing
Parallel operation capability
Fault isolation protection per circuit
Individual monitoring points
Asymmetric loading capability (±10%)
Installation & Maintenance Protocol
Ensure optimal performance in switchgear applications:
Verify cabinet dimensions ≥500×400×600mm (W×D×H)
Use compression lugs rated for 300A connections
Maintain minimum 50mm clearance for airflow
Torque power terminals to 40 N·m ±5%
Perform semi-annual insulation resistance tests
Monitor reactor temperature quarterly
Safety & Protection Features
Engineered for reliable operation:
Arc-resistant barriers
Over-temperature cut-off with auto-reset
Surge protection (10kV/20μs withstand)
Ground continuity monitoring
IP52-rated enclosure for dust protection
Compliance & Standards
Meets international requirements including:
IEC 61000-3-12 harmonic emissions
IEEE 519-2022 harmonic control
EN 62271-200 switchgear standards
UL 1283 EMI filter safety
RoHS 3 compliance
For lightweight EMI solutions or technical datasheets, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.