100kVA ~ 200kVA Range
LQLVF 100kVA/2×250A Power Noise Filter: Wide Frequency EMI Suppression with ONAN Cooling
Broad-Spectrum Noise Attenuation
Engineered for critical EMI suppression across extended frequency ranges:
20KHz-100KHz range: >40dB attenuation
100KHz-1000KHz range: >60dB attenuation
Wide operational frequency: 50-120Hz
Verified per IEC 61000-4-7 harmonic measurement standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 100kVA |
Voltage Rating | Primary/Secondary: 0.4kV |
Current Rating | Primary/Secondary: 250A |
Phase Configuration | Single Phase |
Frequency Range | 50-120Hz |
Cooling System | ONAN (Oil Natural Air Natural) |
Insulation Level | 3kV/1min withstand |
Advanced ONAN Cooling Technology
Optimized thermal management for extended frequency operation:
Mineral oil insulation with natural convection cooling
Temperature rise limit: 60°C at full load
Designed for ambient temperatures up to 45°C
Expansion tank with nitrogen cushion
Radiator fins optimized for variable frequency cooling
Wide Frequency Operation
Specialized design for variable frequency applications:
50-120Hz operational range (±2% stability)
Frequency-independent attenuation performance
Automatic impedance matching circuitry
Core saturation protection at frequency extremes
Harmonic resonance damping technology
Industrial Applications
Ideal for variable frequency power systems:
Variable speed drive (VSD) power conditioning
Frequency converter output filtering
Test bench power supplies
Specialized motor control systems
Research and development facilities
Power electronics laboratories
Dual-Circuit Design Features
Enhanced flexibility for complex systems:
Independent primary and secondary circuits
Differential current monitoring
Asymmetric loading capability (±10%)
Individual circuit protection devices
Parallel operation capability
Installation & Maintenance Protocol
Ensure optimal performance with these guidelines:
Maintain minimum 400mm clearance for natural convection
Verify oil dielectric strength ≥40kV before commissioning
Perform frequency sweep tests annually (50-120Hz)
Check bushing connections quarterly (60 N·m torque)
Monitor oil temperature during frequency transitions
Test attenuation performance at 60Hz, 90Hz and 120Hz
Safety & Protection Systems
Engineered for reliable variable frequency operation:
Pressure relief device with alarm contacts
Dual RTD temperature sensors (oil and core)
Overfluxing protection for frequency extremes
Moisture-controlled breather system
Short-circuit withstand: 20kA for 500ms
Compliance & Standards
Meets international requirements including:
IEC 60076 power reactor standards
IEEE C57.12.00 liquid-immersed equipment
EN 50588-1 medium-power transformers
IEC 61000-3-12 harmonic emissions
ANSI/IEEE C57.96 reactor practice guide
For custom frequency range configurations or technical support, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.