100kVA ~ 200kVA Range
LQLVF 125kVA/2*208A Power Noise Filter: Premium EMI Suppression for Switchgear Systems
High-Performance Noise Attenuation
Engineered for critical EMI suppression in 0.6kV power distribution systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Ultra-low background partial discharge: <2pC
Filter reactor quality factor: >70
Verified per IEC 60270 partial discharge standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 125kVA |
Rated Voltage | 0.6kV Input/Output |
Current Rating | 2 × 208A |
Frequency | 50Hz |
Circuit Configuration | Dual independent circuits |
Insulation Level | 5kV/1min withstand |
Weight | 280kg (robust construction) |
Ultra-Low Partial Discharge Design
Advanced engineering for sensitive electrical environments:
Background PD level <2pC at rated voltage
Triple-shielded reactor construction
Corona-suppression encapsulation technology
PD-monitoring compatible terminal points
Validated per IEEE 1434 measurement standards
Robust Switchgear Integration
Optimized for substation switchgear cabinets:
Heavy-duty 280kg construction for vibration resistance
Standardized mounting points for retrofitting
Front-access terminals for maintenance
Thermal management designed for enclosed spaces
Cable entry points compatible with standard gland plates
Enhanced Insulation System
Superior electrical protection for 0.6kV systems:
5kV/1min dielectric strength (exceeds IEC 60664 requirements)
Class F insulation system (155°C rating)
Creepage distance: ≥20mm/kV
Corona-free design up to 1.2× rated voltage
Partial discharge inception voltage >3.5kV
Industrial Applications
Ideal for 0.6kV systems in:
Industrial substation switchgear
Power distribution units (PDUs)
Manufacturing plant MCC panels
Renewable energy converter stations
Critical facility power systems
High-voltage test laboratories
Dual-Circuit Advantages
Operational flexibility and reliability:
Independent circuits for load balancing
Parallel operation capability
Fault isolation protection per circuit
Individual monitoring points for each filter line
Asymmetric loading capability (±15%)
Installation & Maintenance Protocol
Ensure optimal performance in switchgear applications:
Verify switchgear compartment dimensions ≥600×500×700mm
Use copper busbars with ≥40kA SCCR rating
Maintain minimum 75mm clearance for heat dissipation
Perform semi-annual partial discharge scans
Test insulation resistance annually (≥500MΩ at 2.5kV DC)
Check torque values on power terminals (65 N·m)
Safety & Protection Features
Engineered for reliable operation:
Arc-resistant containment barriers
Thermal overload protection with auto-reset
Surge protection (15kV/20μs withstand)
Ground fault monitoring
Vibration-dampened mounting system
IP54-rated enclosure for contaminant protection
Compliance & Standards
Meets international requirements including:
IEC 62271-200 for AC metal-enclosed switchgear
IEEE 386 separable insulated connectors
IEC 61000-3-12 harmonic emissions
EN 50522 earthing of power installations
ANSI/IEEE C57.12.90 test code
For switchgear-specific installation guides or technical support, contact our engineering team. Performance validated per IEC 61000-4-7 harmonic measurement standards.