100kVA ~ 200kVA Range
LQLVF 160kVA/2x266.7A Power Noise Filter: High-Voltage EMI Suppression for Switchgear Systems
Premium HV Noise Attenuation
Engineered for critical EMI suppression in 3kV industrial power systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Filter reactor quality factor: >70
Dual-frequency compatibility (50-60Hz)
Verified per IEC 61000-4-7 measurement standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 160kVA |
Rated Voltage | 3kV Input/Output |
Current Rating | 2 × 266.7A (533.4A total) |
Frequency Range | 50-60Hz |
Circuit Configuration | Dual Independent Circuits |
Insulation Level | 5kV/1min withstand |
Weight | 280kg (robust construction) |
Installation | Sub-stage switchgear cabinet |
High-Voltage Design Features
Specialized engineering for 3kV applications:
533.4A total current capacity (2×266.7A)
Enhanced creepage distance: ≥25mm/kV
Corona-free design up to 3.6kV operational voltage
Partial discharge inception voltage >4.2kV
Class H insulation system (180°C rating)
Switchgear Integration Design
Optimized for HV switchgear cabinet installations:
Heavy-duty 280kg construction for vibration resistance
Standardized mounting points for retrofitting
Front-access terminals with safety shrouds
Thermal management for enclosed high-heat environments
HV cable entry points with silicone rubber grommets
Forced-air cooling compatibility
Advanced Filter Reactor Technology
High-performance components for superior EMI suppression:
Quality factor >70 for precise frequency targeting
Grain-oriented silicon steel core
Vacuum pressure impregnated windings
Embedded RTD sensors for temperature monitoring
Frequency-stable design (±0.5% across 50-60Hz range)
Industrial Applications
Ideal for 3kV systems in:
Industrial HV switchgear installations
Mine power distribution centers
Marine vessel power systems
Railway traction substations
Large motor drive systems
High-voltage test laboratories
Safety & Protection Systems
Engineered for reliable HV operation:
Arc-resistant containment chambers
Over-temperature protection with lockout
Surge protection (20kV/20μs withstand)
Ground fault monitoring with isolated relays
Automatic discharge circuits
IP55-rated enclosure for harsh environments
Installation & Maintenance Protocol
Ensure optimal performance in HV switchgear:
Verify cabinet dimensions ≥700×600×900mm (W×D×H)
Use silicone-insulated HV cable (8kV rating minimum)
Maintain minimum 150mm clearance to grounded surfaces
Torque HV terminals to 100 N·m ±3%
Perform semi-annual power factor/dissipation factor tests
Test insulation resistance annually (≥500MΩ at 5kV DC)
Conduct partial discharge scans every 6 months
Compliance & Standards
Meets international HV requirements:
IEC 62271-200 for AC metal-enclosed switchgear
IEEE C57.12.00 liquid-immersed equipment
EN 50522 earthing of power installations
IEC 60076-6 power reactor standards
ANSI/IEEE C57.12.90 test code
IEC 61000-3-12 harmonic emissions
For HV switchgear integration guides or custom solutions, contact our specialized engineering team. Performance validated per IEC 60270 partial discharge standards.