100kVA ~ 200kVA Range
LQLVF 200KVA/2*500A Power Noise Filter: High-Current EMI Suppression with ONAN Cooling
Premium Noise Attenuation Performance
Engineered for critical EMI suppression in high-current 0.4kV systems:
40KHz-100KHz range: >40dB attenuation
100KHz-1MHz range: >60dB attenuation
Ultra-low background partial discharge: <3pC
Filter reactor quality factor: >70
Verified per IEC 60270 partial discharge standards
Technical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 200KVA |
Voltage Rating | Input/Output: 0.4kV |
Current Rating | Input/Output: 500A |
Phase Configuration | Single Phase |
Frequency | 50Hz |
Cooling System | ONAN (Oil Natural Air Natural) |
Insulation Level | 3kV/1min (no abnormal discharge) |
Duty Cycle | 15 min ON / 15 min OFF (8 cycles/day) |
Advanced ONAN Cooling Technology
Optimized thermal management for high-current intermittent operation:
Mineral oil insulation with natural convection cooling
Designed for 65°C average oil temperature rise
Temperature stabilization time: <8 minutes after startup
Sealed tank with nitrogen blanket protection
Optimized radiator fins for rapid heat dissipation
Intermittent Duty Operation
Engineered for demanding operational cycles:
15-minute full-power operation cycles
8 cycles per day maximum
Automatic cooldown monitoring system
Thermal memory protection for sequential cycles
Duty cycle counter with maintenance alerts
High-Current Capability
Robust design for industrial power applications:
500A continuous current rating
Low-loss design (efficiency >98% at full load)
Copper windings with 150% overload capacity
Dynamic response time <5ms for load variations
Short-circuit withstand: 25kA for 100ms
Industrial Applications
Ideal for intermittent high-power processes:
Industrial resistance welding equipment
Large induction heating systems
High-power test facility power conditioning
Pulse power systems
Foundry and smelting operations
High-current laboratory experiments
Installation & Maintenance Protocol
Ensure optimal performance with these guidelines:
Maintain minimum 500mm clearance for natural convection
Verify oil level monthly (visible in sight glass)
Perform dielectric oil testing annually (BDV ≥45kV)
Check bushing connections quarterly (85 N·m torque)
Monitor duty cycle counter for maintenance scheduling
Conduct infrared thermography during operational cycles
Safety & Protection Features
Engineered for reliable operation in demanding environments:
Pressure relief diaphragm with alarm contacts
Oil temperature monitoring with dual RTDs
Automatic Buchholz relay for gas detection
Moisture-absorbing breather with silica gel indicator
Grounding terminals on all accessible metal parts
Compliance & Standards
Meets international requirements including:
IEC 60076 power transformer standards
IEEE C57.12.00 for liquid-immersed equipment
EN 50588-1 medium-power transformers
IEC 61000-3-12 harmonic emissions
ANSI/IEEE C57.91 thermal loading guide
For custom duty cycle configurations or technical support, contact our engineering team. Performance validated per IEEE 1137-2018 test standards.