High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

100kVA ~ 200kVA Range

LQLVF 150kVA/2*50A Power Noise Filter | 3kV Switchgear EMI Solution

150kVA dual-circuit noise filter for 3kV switchgear with >70 Q-factor, <5pC partial discharge, and 18kV insulation. 60dB attenuation for critical systems.


  • US$ 2,996.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF 150kVA/2*50A Power Noise Filter: High-Voltage EMI Suppression for Switchgear Systems

Premium Noise Attenuation Performance

Designed for critical EMI suppression in 3kV power distribution systems:

  • 40KHz-100KHz range: >40dB attenuation

  • 100KHz-1MHz range: >60dB attenuation

  • Filter reactor quality factor: >70

  • Background partial discharge: <5pC (per IEC 60270)

Technical Specifications

ParameterSpecification
Rated Capacity150kVA
Rated Voltage3kV Input/Output
Current Rating2 × 50A
Frequency Range50-60Hz
Insulation Level18kV/1min withstand
Continuous Operation60 min at 100% rated load
Weight260kg (robust construction)

High-Voltage Insulation System

Engineered for 3kV switchgear environments:

  • 18kV/1min dielectric strength (exceeds IEC 60664-1 requirements)

  • Triple-coat epoxy resin encapsulation

  • Creepage distance: ≥25mm/kV

  • Corona-free design up to 4kV

Switchgear Integration Design

Optimized for substation switchgear cabinets:

  • Compact dimensions for retrofitting existing compartments

  • Front-access terminal connections

  • Vibration-dampened mounting system

  • Forced-air cooling compatibility

  • Cable entry points compatible with standard gland plates

Critical Applications

Ideal for 3kV power systems in:

  • Industrial substation switchgear

  • Mining power distribution centers

  • Marine vessel power systems

  • OEM equipment integration

  • High-voltage test laboratories

Advanced Reactor Technology

High-performance filtering components:

  • Quality factor >70 for precise frequency targeting

  • Grain-oriented silicon steel cores

  • Vacuum pressure impregnated windings

  • Thermal sensors embedded in hotspot locations

  • Frequency compensation for 50/60Hz systems

Installation & Maintenance Protocol

Ensure optimal performance in switchgear applications:

  1. Verify switchgear compartment dimensions ≥600×400×650mm

  2. Use Class H insulation-rated connections

  3. Perform annual power factor tip-up tests

  4. Monitor partial discharge levels semi-annually

  5. Check torque values on power terminals (50N·m ±5%)

  6. Validate attenuation performance every 24 months

Compliance & Standards

Meets international requirements including:

  • IEC 62271-200 for AC metal-enclosed switchgear

  • IEEE 386 separable insulated connectors

  • EN 50522 earthing of power installations

  • ANSI/IEEE C57.12.90 test code

  • IEC 60076-6 reactor standards

For switchgear-specific integration guides or technical support, contact our HV engineering team. Performance validated per IEC 61000-4-7 harmonic measurement standards.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message