LQLVF-100kVA/2×263.2A Power Noise Filter | 50Hz Single-Phase EMI Suppression

100kVA single-phase noise filter with 263.2A rating, ONAN cooling, and <10pC partial discharge. 60dB EMI attenuation for 50Hz systems.


  • US$ 2,787.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQLVF-100kVA/2×263.2A Power Noise Filter: Premium EMI Suppression for 0.38kV Systems

Ultra-Low Noise Performance

Engineered for critical EMI suppression in industrial 50Hz applications:

  • 40KHz-100KHz: >40dB attenuation

  • 100KHz-1MHz: >60dB attenuation

  • Partial Discharge (PD) Level: <10pC at rated voltage

  • Verified per IEC 60270 partial discharge standards

Technical Specifications

ParameterSpecification
Rated Capacity100kVA
Phase ConfigurationSingle Phase
Voltage RatingInput/Output: 0.38kV
Current RatingInput/Output: 263.2A
Frequency50Hz
Cooling SystemONAN (Oil Natural Air Natural)
Insulation Level3kV/1min (no abnormal discharge)
Continuous Operation60 min at 100% rated load

Advanced ONAN Cooling Technology

Optimized thermal management for extended operation:

  • Mineral oil insulation with natural convection cooling

  • Temperature rise limit: 65°C at full load

  • Designed for ambient temperatures up to 45°C

  • Sealed tank construction with nitrogen cushion

Critical Applications

Ideal for noise-sensitive 0.38kV systems:

  • Industrial motor control centers (MCCs)

  • Precision manufacturing equipment

  • Medical imaging power systems

  • Data center UPS inputs

  • Laboratory measurement systems

Safety & Reliability Features

Engineered for mission-critical operation:

  • Ultra-low partial discharge (<10pC) design

  • Double-sealed bushings with silicone rubber insulation

  • Pressure-relief diaphragm for overload protection

  • Corrosion-resistant steel tank

  • Built-in oil temperature and level indicators

Installation & Maintenance

Optimal performance guidelines:

  1. Maintain minimum 500mm clearance for airflow

  2. Verify oil dielectric strength ≥45kV/2.5mm annually

  3. Perform infrared thermography scans quarterly

  4. Check bushing torque values (35N·m ±10%) during commissioning

  5. Monitor partial discharge levels biannually

Compliance Standards

Meets international requirements including:

  • IEC 60076 for power transformers/reactors

  • IEEE C57.12.00 for liquid-immersed equipment

  • EN 50588-1 for medium-power transformers

  • IEC 61000-3-12 for harmonic emissions

For technical datasheets or custom solutions, contact our engineering team. Performance validated per IEEE 1128-2018 EMI filter testing standards.