High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Oil Testing Instrument

LQHV-655 Open Cup Flash Point Tester | Dual-Function Flash/Ignition Point Analyzer

Dual-function LQHV-655 tester measures open flash & ignition points per ASTM D92/GB3536-2008. Features ±1.5°C accuracy, auto-cooling, and 1,000+ data storage.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-655 Open Cup Flash Point & Ignition Point Tester

ARM-controlled dual-test analyzer for petroleum product flammability assessment

Product Parameters

Technical Parameters

Measurement rangeRoom temperature~400 ℃
Detection typeOpen flash point or ignition point
Temperature detectionplatinum
Accuracy±1℃
Repeatabilityconform to GB3536-2008(ASTM D92)、GB/T 267-88
DisplayColor LCD display
Information storageCan store 1000 measurement results
Ignition methodelectric ignition
Cooling methodForced air cooling
PrinterDot matrix thermal printer
Self inspection functionLifting rod, sweeping rod, printing, etc
Power≤600VA
Using the power supplyAC 220V ± 11V, frequency 50Hz ± 2.5Hz
Ambient temperature10~35℃
Ambient humidity≤90%
WeightAbout 17kg

Complies with: ASTM D92 | GB3536-2008 | GB/T 267-88

Key Advantages

  • 🔥 Dual-Function Testing - Measures both flash and ignition points in one cycle

  • 🎯 Precision Heating - ±1.5°C temperature control (0.1°C resolution)

  • 💾 Extended Memory - Stores 1,000+ test records with timestamps

  • Electric Ignition - No combustible gas required (enhanced lab safety)

Testing Process

  1. Sample Preparation - 70±5ml oil poured into brass test cup

  2. Test Initiation:

    • Electric igniter positioned 5mm above cup rim

    • PID-controlled heating ramp

  3. Dual Detection:

    • Flash Point - First flame appearance (≥5mm height)

    • Ignition Point - Sustained burning (≥5 seconds)

  4. Auto Shutdown - Cooling fan activates post-test

Safety Systems

  • 🛡️ Over-Temp Protection - Cuts power at 410°C

  • 🛡️ Spill Containment - Built-in fire-resistant tray

  • 🛡️ Visual Alerts - Flashing LED during ignition cycles

Typical Test Results

SampleFlash PointIgnition Point
Transformer Oil (Mineral)145-160°C165-185°C
Diesel Fuel52-96°C60-110°C

Why This Tester?

FeatureLQHV-655Manual Methods
Test Time20-25 minutes60+ minutes
Data TraceabilityDigital recordsPaper logs

Maintenance Protocol

  • 🧽 Post-Test - Clean cup with toluene/acetone mix

  • 📅 Monthly - Verify with certified reference oils

  • 🔍 Annually - Calibrate temperature sensors

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message