LQHV-645 Oil Dissolved Gas Analyzer | DGA Chromatograph for Transformer Fault Detection

Industrial-grade LQHV-645 DGA analyzer detects transformer faults via gas chromatography. Features Ethernet connectivity, 4-detector capacity, and remote diagnostics.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-645 Oil Dissolved Gas Chromatograph

Advanced dissolved gas analysis (DGA) system for predictive maintenance of power transformers and hydrogen-cooled generators

Product Parameter

Key Technical Indexes

Network anti-control systemInternal CAN's way, with interface board design, It can be converted to network port output at will
Signal output bits24-bit
Communication interfaceNetwork interface output(class 6 network cable connections)
Circuit designARM embedded design for easy wireless control, remote control and mobile app control
Temperature control systemSix-way independent temperature control
Temperature controlRoom temperature - 450 ℃, liquid nitrogen refrigeration: - 80 ℃ - 450 ℃
Column box temperature control accuracy±0.02℃
Program heating up21 Stage 21 level, 0.1 ℃ / stage
Show moduleLarge-screen LCD
Display accuracy0.01 ℃
Lift rate of column and box0~80 ℃ / min (adjustment increment 0.1 ℃ / min) up to 120 ℃ / min
Temperature reprogrammed repeatability≤1%
TCD detector sensitivityS value ≥ 10000mv.ml/mg (benzene) )up to 12000 mv.ml/mg (benzene)
Baseline noise≤10uv
Baseline Drift≤50uv/30min
Detection limit of FID detector≤5 x 10-12g/s(cetane)
Baseline noise≤2 x 10-14A
Baseline Drift≤1×10-13A/30min(After the instrument stabilizes for 2 hours)
Detection limit of ECD detector≤1.0 x 10-13g/s (r-666)
Baseline noise≤40uv
Baseline Drift≤100uv/30min
Detection limit of FPD detector≤1.4 x 10-12 g/s(p), ≤5×10-11g/s(S)
Baseline noise≤20uv
Baseline Drift≤50uv/30min
Extended≤6 external events can be added
Automation engineeringCan be increased: automatic ignition function, automatic sampler connection, four-way flow pressure display function, optional counter-control workstation to achieve counter-control

Compliant with: IEC 60567 | ASTM D3612 | DL/T 722

Key Features

  • 🔬 Multi-Detector Configuration – Supports simultaneous FID/TCD/ECD/FPD detection

  • 🌐 Industrial IoT Ready – 10/100M Ethernet with Modbus/TCP integration

  • 📊 Centralized Monitoring – Manages up to 253 chromatographs in one network

  • Precision Control – EPC/EFC with ±0.01psi pressure stability

Diagnostic Capabilities

Fault Gas Detection

  • Acetylene (C2H2) – Arcing >5ppm

  • Hydrogen (H2) – Partial discharge >100ppm

  • Methane (CH4) – Thermal faults >50ppm

Condition Monitoring

  • Rogers Ratio analysis

  • Duval Triangle interpretation

  • Key gas method trending

System Architecture

Modular Design

  1. Sample Introduction – Headspace/on-line sampler

  2. Chromatographic Separation:

    • Packed column (C1-C2 hydrocarbons)

    • Molecular sieve (H2/O2/N2)

  3. Detection & Analysis – Multi-detector data fusion

Smart Connectivity

  • 🖥️ Remote Diagnostics – Manufacturer VPN troubleshooting

  • 📱 Multi-Level Access – Lab/QC/management dashboards

  • 🔄 Agilent/Waters Compatibility – AIA-standard CDF files

Why Choose LQHV-645?

FeatureLQHV-645Conventional GC
Analysis Speed15 min/full profile30+ minutes
Detection Limits0.1ppm (C2H2)1ppm

Operational Advantages

  • 🔧 Self-Calibration – Automatic baseline correction

  • Scheduled Operation – Pre-programmed overnight runs

  • 🔄 Future-Proof – Detector upgrades without hardware change