Oil Testing Instrument
LQHV-645 Oil Dissolved Gas Chromatograph
Advanced dissolved gas analysis (DGA) system for predictive maintenance of power transformers and hydrogen-cooled generators
Product Parameter
Key Technical Indexes
Network anti-control system | Internal CAN's way, with interface board design, It can be converted to network port output at will | |
Signal output bits | 24-bit | |
Communication interface | Network interface output(class 6 network cable connections) | |
Circuit design | ARM embedded design for easy wireless control, remote control and mobile app control | |
Temperature control system | Six-way independent temperature control | |
Temperature control | Room temperature - 450 ℃, liquid nitrogen refrigeration: - 80 ℃ - 450 ℃ | |
Column box temperature control accuracy | ±0.02℃ | |
Program heating up | 21 Stage 21 level, 0.1 ℃ / stage | |
Show module | Large-screen LCD | |
Display accuracy | 0.01 ℃ | |
Lift rate of column and box | 0~80 ℃ / min (adjustment increment 0.1 ℃ / min) up to 120 ℃ / min | |
Temperature reprogrammed repeatability | ≤1% | |
TCD detector sensitivity | S value ≥ 10000mv.ml/mg (benzene) )up to 12000 mv.ml/mg (benzene) | |
Baseline noise | ≤10uv | |
Baseline Drift | ≤50uv/30min | |
Detection limit of FID detector | ≤5 x 10-12g/s(cetane) | |
Baseline noise | ≤2 x 10-14A | |
Baseline Drift | ≤1×10-13A/30min(After the instrument stabilizes for 2 hours) | |
Detection limit of ECD detector | ≤1.0 x 10-13g/s (r-666) | |
Baseline noise | ≤40uv | |
Baseline Drift | ≤100uv/30min | |
Detection limit of FPD detector | ≤1.4 x 10-12 g/s(p), ≤5×10-11g/s(S) | |
Baseline noise | ≤20uv | |
Baseline Drift | ≤50uv/30min | |
Extended | ≤6 external events can be added | |
Automation engineering | Can be increased: automatic ignition function, automatic sampler connection, four-way flow pressure display function, optional counter-control workstation to achieve counter-control |
Compliant with: IEC 60567 | ASTM D3612 | DL/T 722
Key Features
🔬 Multi-Detector Configuration – Supports simultaneous FID/TCD/ECD/FPD detection
🌐 Industrial IoT Ready – 10/100M Ethernet with Modbus/TCP integration
📊 Centralized Monitoring – Manages up to 253 chromatographs in one network
⚡ Precision Control – EPC/EFC with ±0.01psi pressure stability
Diagnostic Capabilities
Fault Gas Detection
Acetylene (C2H2) – Arcing >5ppm
Hydrogen (H2) – Partial discharge >100ppm
Methane (CH4) – Thermal faults >50ppm
Condition Monitoring
Rogers Ratio analysis
Duval Triangle interpretation
Key gas method trending
System Architecture
Modular Design
Sample Introduction – Headspace/on-line sampler
Chromatographic Separation:
Packed column (C1-C2 hydrocarbons)
Molecular sieve (H2/O2/N2)
Detection & Analysis – Multi-detector data fusion
Smart Connectivity
🖥️ Remote Diagnostics – Manufacturer VPN troubleshooting
📱 Multi-Level Access – Lab/QC/management dashboards
🔄 Agilent/Waters Compatibility – AIA-standard CDF files
Why Choose LQHV-645?
Feature | LQHV-645 | Conventional GC |
---|---|---|
Analysis Speed | 15 min/full profile | 30+ minutes |
Detection Limits | 0.1ppm (C2H2) | 1ppm |
Operational Advantages
🔧 Self-Calibration – Automatic baseline correction
⏰ Scheduled Operation – Pre-programmed overnight runs
🔄 Future-Proof – Detector upgrades without hardware change