Tank Type
HTRS 100kV/1800kVA (60kV) Resonant Reactor
Voltage Operating Modes
Voltage | Current | Inductance | Load Range |
---|---|---|---|
60kV | 30A | 5.3H | 0.16μF ~ 1.327μF |
100kV | 18A | 14.737H | 0.048μF ~ 0.478μF |
Technical Parameters
Electrical
Frequency: 60Hz ±0.5%
Capacity: 1800kVar
THD: ≤1% (IEC 61000-4-7)
Performance
Q Factor: >30
Adjustment Range: 15:1 inductance ratio
Insulation: 25# oil (IEC 60296)
Reliability Features
Dielectric Strength
Withstand Voltage: 110% rated for 1min
Temperature Rise:
Winding: ≤65K
Oil: ≤45K (improved thermal performance)
Operational Limits
Duty Cycle: 1h ON/1h OFF (4×/day)
Cooling: ONAN (Oil Natural Air Natural)
Engineering Design
Adjustment System
Control: Electric stepless adjustment
Material: 1Ni18Cr9Ti non-magnetic stainless
Noise: Double lead screw (≤75dB)
Enclosure
Pressure Test: 20kPa (GB/T 7354)
Seals: Aviation acrylate (MIL-R-25988)
Coating: Sky blue epoxy (ISO 12944 C4)
Standards Compliance
IEC 60060-1 (High-voltage testing)
IEC 60270 (Partial discharge)
IEEE C57.12.90 (Temperature rise)