Cylinder Type
HCRS 750kV/7500kVA Three-Stage Resonant Reactor System
Product Overview
The HCRS 750kV/7500kVA three-stage resonant reactor system represents cutting-edge high voltage testing technology, compliant with IEC 60-1 standards. This outdoor-capable system delivers exceptional 7500kVA capacity through three 250kV stages, featuring Q>50 performance and robust construction for demanding field testing applications.
Standards Compliance
IEC 60-1 High Voltage Test Technique
IEC 1000 Electromagnetic Compatibility
GB1094 Reactor Standards
GB/T 1094.10-2004 Sound Level Measurement
B8749-1998 Voltage Regulator Requirements
System Specifications
Parameter | Specification |
---|---|
Rated Capacitance | 7500kVA |
Rated Voltage | 750kV (250kV/stage) |
Rated Current | 10A |
Rated Frequency | 50Hz |
System Quality Factor (Q) | >50 |
Partial Discharge | <2pC (factory test) 50-100pC (field conditions) |
Waveform Deviation | ≤1.5% |
Inductance Range | 125-2600H |
Single Module Specifications (HCRS 250kV/2500kVA)
Parameter | Specification |
---|---|
Rated Capacity | 2500kVA |
Voltage Configuration | 250kV (single) 750kV (3-stage) |
Rated Current | 10A |
Cooling Method | ONAN |
Noise Level | ≤70dB |
Inductance Range | 65-1300H |
Performance Characteristics
Overload Capability
Current: 11A (110%) for 300s - no winding damage
Voltage: 825kV (system) / 275kV (module) at 110% for 60s - no insulation damage
Outdoor Operation
Verified operation in rain/snow conditions
Epoxy insulation skirt protection
Maintains performance in field environments
Physical Dimensions
Single Module: 3500mm (Diameter) × 7200mm (Height)
Advanced Design Features
Core Construction
Grain-oriented electrical steel (130-0-130)
Chip-removal treatment with curing agent
Noise reduction technology (≤70dB)
Adjustable Reactance System
Precision air gap adjustment
Guide rail system for accurate coil alignment
Stainless steel brackets minimize eddy current losses
Environmental Protection
Weather-resistant epoxy insulation
Robust outdoor construction
Reliable grounding baffles between windings
Quality Assurance
60+ year design lifespan
Developed with leading research institutions
Field-proven 2250kV/2A transformer reference
Continuous quality improvements