Cylinder Type
HCRS 1500kV/15000kVA Industrial Resonant Test System
Unmatched Power Capacity
Total Rating: 15000kVA (Industry-leading capacity)
Current Range: 10A-30A (Parallel configuration supported)
Frequency Range: 50-150Hz (Extended quality factor Q≥50)
Configuration Matrix
Connection | Voltage | Current | Inductance Range (H) | Load Range (nF) |
---|---|---|---|---|
Single Module | 500kV | 10A | 66.6-845.2 | 12-1523 |
Two Serial | 1000kV | 10A | 133.2-1690.4 | 6-76.1 |
Three Serial | 1500kV | 10A | 199.8-2535.6 | 4-50.8 |
Two Parallel | 500kV | 20A | 33.3-422.6 | 24-3046 |
Three Parallel | 500kV | 30A | 22.2-281.7 | 36-4569 |
Precision Performance
Partial Discharge: <10pC @1500kV, <2pC @1200kV
Waveform Fidelity: ≤1.5% THD (IEC 60060-1 compliant)
Measurement: Class 1 accuracy (0.5% reading)
Noise Control: ≤70dB @5m (Industrial environment compliant)
Thermal Management System
Operating Mode | Duration | Temperature Rise |
---|---|---|
100% Rated Load | 1hr ON/1hr OFF (8 cycles) | ΔT≤65K (Winding), ≤45K (Oil) |
66% Rated Load | Continuous | ΔT≤50K (Winding), ≤35K (Oil) |
Smart Protection System
Multi-stage Protection: Over-voltage/current + flashover + dual air gap limits
Auto-calibration: Self-returning to zero position after testing
Phase Guardian: Motor reversal and phase sequence protection
Gap Monitoring: Real-time air gap display (0.1mm resolution)
Impedance Matching: ≤5% deviation between modules
Engineering Innovations
Core Technology
Magnetic Core: 30-0-130 grain-oriented steel with vibration damping treatment
Noise Reduction: Chip-free cores with polymer curing (70dB industry benchmark)
Modular Design: Quick-connect HV busbars and alignment guides
Control System
Resonance auto-tuning at 1-1.5kV excitation voltage
Failsafe transmission with backup mechanical stops
Remote gap adjustment via control console
Certification & Compliance
IEC 60270 Partial Discharge Standard
IEEE Std 4-2013 High-Voltage Testing
ANSI/NETA ATS-2017 Acceptance Testing
CE Marked for EU Safety Compliance
Engineering Insight: The system's ultra-wide load range (4-4569nF) covers testing scenarios from GIS components (typically 10-100pF) to extra-long submarine cables (up to 5μF) through flexible module configurations.
Project Planning Data
Parameter | Value |
---|---|
Input Power | 400V±10%, 50Hz (Customizable to 60Hz) |
System Lifetime | 60+ years (200,000 operations design) |
Commissioning | 72-hour factory acceptance test included |
Maintenance | 5-year calibration interval recommended |