Cylinder Type
HCRS 1500kV/4500kVA Resonant Test System Technical Overview
System Configuration
The HCRS series resonant test system features modular design with three operation modes:
Three-stage configuration: 1500kV/3A output
Two-stage configuration: 1000kV/3A output
Parallel connection: 500kV/6A output
Core Technical Parameters
Parameter | Specification |
---|---|
Input Voltage | 0.38kV ±10% |
Input Current | 263A (two-phase) |
Quality Factor | Q≥45 @60Hz |
Waveform Deviation | <1% THD |
Measurement Accuracy | Grade 1 (effective value) |
Noise Level | ≤70dB at rated operation |
Load Compatibility
Optimized for testing various capacitive loads:
1500kV output: 5305pF (with voltage divider)
1000kV output: 79600pF (with voltage divider)
500kV single-stage: 31830pF (with voltage divider)
500kV parallel: 37130pF (with voltage divider)
Insulation & Safety Features
Withstands 1650kV (1.1× rated voltage) for 1 minute
Partial discharge <5pC at 100% rated voltage
Dual epoxy resin tubes with stainless steel brackets
Temperature monitoring with ΔT≤65K (winding), ≤55K (oil)
Advanced Structural Design
Core material: 30-0-100 grain-oriented electrical steel
Adjustable air gap design with guide rail system
Eddy current reduction through special curing process
Thermal expansion compensation for oil-filled system
Grounding shields between windings and core
Operational Specifications
Duty cycle: 1 hour ON / 1 hour OFF (6 cycles daily)
Continuous operation: 60min at rated load
Design life: >60 years
Cooling: ONAN (Oil Natural Air Natural)
Single-Stage Reactor (HCRS 500kV/1500kVA)
Nominal inductance: 442H (min)
Optimal load capacitance: 15916pF
Quality factor: Q≥60 @60Hz
550kV withstand voltage (1 minute)
This system represents the latest advancement in variable inductance power frequency resonant technology, developed through collaboration with leading research institutions to ensure reliable performance in high-voltage testing applications.