Cylinder Type
HCRS 1200kV/6000kVA 60Hz Resonant Test System
The HCRS 1200kV/6000kVA Inductance Resonant Reactor delivers exceptional 5A output capacity at 1200kV, featuring wide inductance adjustment (4696~723.8H) and industry-leading ≤5pC partial discharge performance for rigorous high-voltage testing applications.
Electrical Specifications
Input Voltage: 0.44kV ±5% (Two-phase a/b 440V)
Frequency: 60Hz
Output Voltage: 1200kV (Three reactors serial connection)
Output Current: 5A (Three reactors serial connection)
Configuration Options:
1200kV @ 11053pF
800kV @ 16579pF
400kV @ 33158pF (all include divider)
Waveform Deviation: <1%
Measuring Accuracy: 1 grade
Performance Parameters
Inductance Range: 4696~723.8H
Quality Factor (Q): ≥45 (without water termination/resistance load)
Noise Level: ≤70dB (rated conditions, 4m distance)
Insulation: Withstands 1min at 1.1× rated voltage
Partial Discharge:
≤5pC @ 100% Un
≤3pC @ 80% Un
Breakdown Testing: Sustains 1100kV without system damage
Operational Modes
Standard Testing Cycle
1 hour ON / 1 hour OFF @ rated voltage/current
Maximum 4 cycles per day
Continuous 3-hour operation @ 900kV
Extended Duty Cycle
20-day continuous operation @ 600kV
Load capacitance: 13250pF (Two reactors serial connection)
Advanced Structural Design
Core Construction: Adjustable iron coil with precision gap tuning
Premium Materials:
30-0-130 grain-oriented electrical steel
Stainless steel brackets with dual epoxy tubes
Thermal Management:
High-intensity magnetic field heat dissipation
Oil expansion/contraction compensation system
Noise Control Technology:
Chip-removed cured iron core
Precision guide rail system for smooth adjustment
Safety Systems:
Reliable grounding baffles between winding/iron core
Comprehensive protection (over-voltage, over-current, flashover)
Air gap limit monitoring
System Features
Linearity: 10%-100% reactance, error ≤±1%
Field Verification: Partial discharge testing at user facility
Design Lifespan: >60 years operational life
Technical Collaboration: Developed with leading research institutions
Conclusion
The HCRS 1200kV/6000kVA Resonant Test System sets new standards for high-current (5A) testing at 1200kV, with its exceptional 60Hz performance and flexible configuration options. The system's robust construction, precise inductance adjustment (4696~723.8H range), and comprehensive safety features make it ideal for demanding high-voltage testing applications requiring 6000kVA capacity.