HCRS 600kV/2400kVA Inductance Resonant Reactor: High-Voltage Testing Solution
Product Overview
The HCRS series cylinder-type single-phase resonant reactor represents the latest advancement in high-voltage testing technology. With 600kV rated voltage and 2400kVA capacity, this system delivers exceptional performance for demanding electrical testing applications.
Key Specifications
Parameter | Value |
---|---|
Rated Voltage | 600kV |
Rated Current | 1A |
Partial Discharge Level | <5pC (rated voltage), <3pC (480kV) |
Frequency Range | 50-200Hz |
Waveform Deviation | ≤1.5% |
Performance Capabilities
Robust Overload Protection
300-second operation at 150% current (1.5A) without winding damage
300-second operation at 110% voltage (660kV) without insulation failure
Continuous Operation Standards
60-minute operation at 100% voltage/current with winding temperature rise ≤65K
Oil temperature rise maintained below 55K during extended operation
Technical Features
Precision Adjustment System
Single-stage inductance: 5071-637H (50Hz)
Series connection inductance: 10142-1273H (50Hz)
Single-stage load capacitance: 2000pF-15922pF (with divider)
Series load capacitance: 1000pF-7967pF (with divider)
Measurement Accuracy
System quality factor (Q): >50 (50-200Hz range)
Measuring system accuracy: 1 grade
Linearity: ±1% across 10%-100% reactance range
Noise level: ≤75dB
Advanced Structural Design
Core Construction
Grain-oriented electrical steel core (30-0-130 grade)
Chip-removal treatment with curing agent for noise reduction
Precision guide rails for vertical/horizontal coil adjustment
Safety Features
Reliable grounding baffles between winding and iron coil
Stainless steel brackets to minimize eddy current losses
Thermal-expansion compensated oil system design
Over-voltage, over-current, and flashover protection
Air gap monitoring (max/min protection)
Engineering Advantages
60+ year operational lifespan through optimized design
Proprietary resonant system architecture
University-validated performance enhancements
Thermally-stable pedestal for high-intensity magnetic fields
Typical Applications
Power cable withstand voltage testing
Transformer and GIS diagnostic testing
High-voltage component qualification
Research laboratory applications
Partial discharge measurement systems
Why Choose HCRS Resonant Reactor?
This reactor system combines decades of high-voltage engineering experience with cutting-edge improvements in resonant test technology. The optimized structural design, superior materials selection, and rigorous quality control ensure reliable performance in critical testing applications.