Cylinder Type
HCRS 500kV/2000kVA Dual-Mode Resonant System
Flexible Configuration Options
Configuration | Voltage | Load Range | Inductance Range |
---|---|---|---|
Single Module | 250kV | 6nF-50.97nF | 199H-1690.4H |
Series Connection | 500kV | 3nF-25.48nF | 398H-3380.8H |
Key Specifications
Parameter | Specification |
---|---|
System Capacity | 2000kVA (1000kVA per stage) |
Current Rating | 4A (4.8A max) |
Quality Factors | System ≥40 | Reactor ≥50 |
Waveform Distortion | ≤1.5% |
Performance Features
Advanced Electrical Performance
Ultra-low partial discharge: <2pC at 500kV
Precision voltage control: ±1% linearity
Wide frequency range: 50Hz operation
Environmental Durability
Outdoor-rated epoxy skirt insulation
Weatherproof design (rain/snow resistant)
Proven field performance up to 700kV
Mechanical Design
Core Construction
30-0-130 grain-oriented silicon steel
Dual epoxy tube insulation system
Stainless steel non-magnetic components
Noise Reduction
Chip-removed steel treatment
Curing agent integration
Precision guide rail system
Safety & Reliability
Test | Condition | Requirement |
---|---|---|
Overcurrent | 110% (4.4A) | 600 seconds |
Overvoltage | 110% (550kV) | 60 seconds |
Environmental | Outdoor conditions | Full performance |
Quality Assurance
60-year design life expectancy
University-developed core technology
Field-proven 2250kV transformer design
Dimensions: 3500mm (Dia) × 7200mm (H) per module