Cylinder Type
HCRS 450kV/900kVA Ultra High Voltage Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 900kVA |
Output Voltage | 450kV (495kV withstand) |
Rated Current | 2A (2.5A max) |
Frequency | 50Hz |
Inductance Range | 573.2H-3380.8H (5.9:1 ratio) |
Performance Highlights
Record Inductance: Up to 3380.8H capability
Ultra-Low PD:
<5pC at 450kV
<3pC at 360kV
High Efficiency: Quality factor >50
Load Characteristics
Parameter | Value |
---|---|
Load Range | 3nF-17.69nF |
Reactance Range | 180kΩ-1061.6kΩ |
Measurement Accuracy | 1-grade |
Mechanical Design
Cylinder-Type Architecture
30-0-130 grain-oriented silicon steel core
Dual epoxy tube construction:
Stainless steel bracketing
±1% linearity
Noise Reduction Technology
Chip-removed steel treatment:
Curing agent integration
≤75dB operation
Precision guide rail system
Safety & Protection
Overload Capability:
125% current (2.5A) for 300s
110% voltage (495kV) for 60s
Protection Systems:
Over-voltage/current
Flashover detection
Air gap monitoring
Operational Parameters
Duty Cycle
Rated Load: 60 minutes continuous
Derated Operation: Unlimited at 80% rating
Thermal Limits:
Winding ΔT≤65K
Oil ΔT≤55K
Quality Assurance
Durability Features
60-year design life
University-developed core technology
Research institute collaboration
Testing Validation
Partial discharge calibration
Thermal imaging verification
Mechanical endurance testing