Cylinder Type
HCRS 450kV/13500kVA Modular Resonant Test System
Flexible Operation Modes
| Configuration | Voltage | Max Load | Inductance |
|---|---|---|---|
| Series Connection | 450kV | 176.8nF | 39.84H |
| Parallel Connection | 225kV | 707.3nF | 9.96H |
| Single Module | 225kV | 353.7nF | 19.92H |
Core Specifications
| Parameter | Specification |
|---|---|
| Rated Capacity | 13500kVA (6750kVA per module) |
| Input Voltage | 3.3kV |
| Rated Current | 30A (33A max) |
| Quality Factor | ≥65 (single module) |
Performance Highlights
Ultra-Low PD: ≤2pC at 450kV
Precision Measurement:
Voltage accuracy <1% (IEC 60060-1)
Waveform distortion ≤1%
Silent Operation: <72dB at rated load
Safety & Protection
| Capability | Condition | Duration |
|---|---|---|
| Overcurrent | 110% (33A) | 300 seconds |
| Overvoltage | 110% (495kV) | 120 seconds |
Modular Design
Cascade Architecture
Two 6750kVA modules (24 tons each)
Synchronized operation:
±5% impedance matching
Integrated transmission system
Advanced Controls
Real-time gap monitoring (1% accuracy)
Auto return-to-zero function
Resonance stability from 1.5kV to 450kV
Mechanical Construction
Cylinder-Type Design
30-0-130 grain-oriented silicon steel core
Dual epoxy tube construction:
Stainless steel bracketing
Precision guide rail system
Noise Reduction
Chip-removed steel treatment:
Curing agent integration
≤75dB/module operation
Quality Assurance
Durability Features
60-year design life
University-developed technology
Research institute collaboration
Testing Validation
Partial discharge calibration
Thermal imaging validation
Mechanical endurance testing