Cylinder Type
HCRS 400kV/1600kVA Precision Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 1600kVA |
Output Voltage | 400kV (440kV withstand) |
Rated Current | 4A (4.4A max) |
Frequency | 60Hz |
Quality Factor | ≥40 |
Performance Highlights
Ultra-Low PD: <2pC at 400kV
Precision Measurement:
Waveform distortion ≤1.5%
1-grade accuracy
Robust Design:
60-year service life
University-developed technology
Safety & Protection
Capability | Condition | Duration |
---|---|---|
Overcurrent | 120% (4.4A) | 300 seconds |
Overvoltage | 110% (440kV) | 60 seconds |
Mechanical Design
Cylinder-Type Architecture
30-0-130 grain-oriented silicon steel core
Dual epoxy tube construction:
Stainless steel bracketing
±1% linearity
Noise Reduction Technology
Chip-removed steel treatment:
Curing agent integration
≤75dB operation
Precision guide rail system
Operational Parameters
Duty Cycle
Rated Load: 60 minutes continuous
Thermal Limits:
Winding ΔT≤65K
Oil ΔT≤55K
Quality Assurance
Durability Features
60-year design life
Research institute collaboration
Continuous improvement program
Protection Systems
Over-voltage/current protection
Flashover detection
Air gap monitoring