Cylinder Type
HCRS 400kV/1200kVA Ultra High Voltage Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 1200kVA |
Output Voltage | 400kV (440kV withstand) |
Rated Current | 3A (3.3A max) |
Frequency | 60Hz |
Inductance Range | 321.7H-2347.8H (7.3:1 ratio) |
Performance Highlights
Ultra-Low PD:
<2pC at 400kV
<3pC at 320kV
Extreme Inductance: Up to 2347.8H capability
Precision Measurement:
Waveform distortion ≤1.5%
1-grade accuracy
Load Characteristics
Parameter | Value |
---|---|
Nominal Load Range | 3nF-21.894nF |
Actual Test Load | 18.894nF |
Quality Factor | ≥40 |
Mechanical Design
Cylinder-Type Architecture
30-0-130 grain-oriented silicon steel core
Dual epoxy tube construction:
Stainless steel bracketing
Precision gap adjustment (±1%)
Noise Reduction Technology
Chip-removed steel treatment:
Curing agent integration
≤75dB operation noise
Guide rail alignment system
Safety & Protection
Overload Capability:
110% current (3.3A) for 300s
110% voltage (440kV) for 60s
Protection Systems:
Over-voltage/current
Flashover detection
Air gap monitoring
Quality Assurance
Standards Compliance
IEC 60-1 (High Voltage Testing)
GB 1094 (Chinese Reactor Standard)
GB/T 1094.10-2004 (Acoustic Measurement)
Durability Features
60-year design life
University-developed technology
Continuous improvement program