Cylinder Type
HCRS 350kV/350kVA Ultra-High Inductance Resonant System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 350kVA |
Rated Voltage | 350kV (385kV withstand) |
Rated Current | 1A (Max 1.1A) |
Inductance Range | 1114H-7230H (6.5:1 ratio) |
Load Range | 0-9094pF (including divider) |
Performance Characteristics
Ultra-Low PD:
<5pC at 350kV
<2pC at 210kV
Extreme Inductance: Up to 7230H capability
Precision Measurement:
Waveform distortion ≤1.5%
1-grade accuracy |
Safety & Protection
Capability | Condition | Duration |
---|---|---|
Overcurrent | 120% (1.1A) | 300 seconds |
Overvoltage | 110% (385kV) | 60 seconds |
Mechanical Design
Cylinder-Type Architecture
30-0-130 grain-oriented silicon steel core
Dual epoxy tube construction:
Stainless steel bracketing
Precision gap adjustment (±1%)
Noise Reduction Technology
Chip-removed steel treatment:
Curing agent integration
<70dB operation noise
Guide rail system:
Vertical/horizontal alignment
University-developed mechanism
Operational Parameters
Duty Cycle
Rated Load: 60 minutes continuous
Thermal Limits:
Winding ΔT≤65K
Oil ΔT≤55K
System Features
Protection Systems:
Over-voltage/current
Flashover detection
Air gap monitoring
Resonance Stability:
Q factor ≥35
Excellent linearity
Quality Assurance
Durability Features
60-year design life
Research institute collaboration
Continuous improvement program
Testing Validation
Partial discharge verification
Thermal cycling tests
Mechanical endurance testing