Cylinder Type
HCRS 350kV/1050kVA Modular Resonant Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 1050kVA |
Output Voltage | 350kV (385kV withstand) |
Rated Current | 3A |
Load Range | 3000pF-30030pF |
Input Power | 380V single-phase, 50Hz |
Performance Highlights
Ultra-Low PD:
<5pC at 350kV
<3pC at 280kV
High Efficiency: Quality factor ≥50
Precision Measurement:
Waveform distortion ≤1%
1-grade accuracy |
Safety & Protection
Feature | Specification |
---|---|
Insulation Level | 385kV/1min |
Protection Systems | Over-voltage, over-current, flashover |
Thermal Limits | Winding ΔT≤65K, Oil ΔT≤55K |
Modular System Design
Key Features
Synchronized Operation:
±5% impedance matching
Integrated transmission shafts
Advanced Controls:
Real-time gap monitoring
Auto return-to-zero function
Resonance Stability
Maintains tuning from 1-1.5kV to 350kV
No detuning during voltage ramps
Precision air gap sensors
Mechanical Construction
Cylinder-Type Architecture
30-0-130 grain-oriented silicon steel core
Dual epoxy tube insulation:
Stainless steel bracketing
±1% linearity
Noise Reduction Technology
Chip-removed steel treatment:
Curing agent integration
≤70dB at 5m
Precision guide rail system
Operational Parameters
Duty Cycle
Rated Load: 60 minutes continuous
Cooling: ONAN (Oil Natural Air Natural)
Quality Assurance
Durability Features
60-year design life
University-developed technology
Research institute collaboration
Factory Testing
Partial discharge verification
Thermal imaging validation
Mechanical endurance testing