Cylinder Type
HCRS 250kV/500kVA Precision Resonant Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 500kVA |
Rated Voltage | 250kV |
Maximum Voltage | 275kV (110% rating) |
Rated Current | 2A |
Input Power | AC 380V±10%, 30kVA |
Performance Characteristics
Ultra-Low PD: <5pC at rated voltage
Wide Load Range: 1.5μF-25.4μF
High Efficiency: Quality factor 30-100
Precision Waveform: <1% THD
Operational Parameters
Mode | Duration |
---|---|
100% Rating | 60 minutes continuous |
2/3 Rating | Unlimited operation |
Advanced Mechanical Design
Cylinder-Type Architecture
Dual epoxy tube construction with:
Stainless steel bracketing
Precision gap adjustment
Core material: 30-0-100 grain-oriented silicon steel
Innovative Features
Chip-removed steel treatment:
Curing agent integration
Noise reduction to <75dB
Guide rail system:
Vertical/horizontal alignment
±1% linearity
Excitation System
Voltage Options: 7.5kV or 15kV input
Power Supply: 380V±10%, 30kVA
Cooling: ONAN (Oil Natural Air Natural)
Quality Assurance
Durability Features
60-year design life
University-developed technology
Research institute collaboration
Safety Systems
Multi-layer grounding baffles
Thermal monitoring:
Winding temperature
Oil temperature
Typical Applications
Precision component HV testing
Research laboratory applications
High-voltage capacitor validation
Partial discharge measurement