Cylinder Type
HCRS 200kV/3000kVA Cylinder-Type Resonant Test System
Electrical Specifications
Parameter | Specification |
---|---|
Rated Capacity | 3000kVA |
Rated Voltage | 200kV |
Rated Current | 15A (Max 16.5A) |
Inductance Range | 42.4H-400H (9.4:1 adjustment ratio) |
Max Load Capacitance | 0.238μF (including divider) |
Performance Highlights
Extended Operation: 20-day continuous @ 160kV/14A
Exceptional Efficiency: System Q factor ≥60
Precision Measurement:
Waveform distortion ≤1%
1-grade measurement accuracy
Low Noise: ≤75dB at 4m distance
Safety & Protection
Feature | Specification |
---|---|
Protection Functions | Over-voltage, over-current, flashover protection |
Air Gap Protection | Max/min gap monitoring |
Thermal Limits | Winding ΔT≤65K, Oil ΔT≤45K |
Advanced Mechanical Design
Cylinder-Type Architecture
Triple-layer construction:
Epoxy tube + metal tube + epoxy tube
Top electrode HV output
Core material: 30-0-130 grain-oriented silicon steel
Innovative features:
Chip-removed steel treatment with curing agent
Precision guide rail system
Durability Features
60-year design life expectancy
Optimized grounding system:
Multi-layer baffle insulation
Redundant grounding points
Control System
Adjustment: Motorized inductance control
Monitoring: Real-time gap measurement
Linearity: ±1% across full reactance range
Typical Applications
High-voltage cable frequency testing
Power transformer diagnostics
GIS partial discharge measurement
Industrial HV component validation
Quality Assurance
Developed in collaboration with:
Leading technical universities
National research institutes
Factory testing includes:
72-hour continuous load test
Partial discharge verification
Mechanical endurance testing