High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kV Range

LQTT 500kV/500kVA Test Transformer | <2pC PD | Precision HV Testing

IEC-compliant 500kV test transformer with <2pC partial discharge at 400kV. 550kV withstand, integrated safety CT & customizable color. Download specs.


>>>WhatsApp Communication<<<

Product Details

Product Tags

LQTT Series 500kV/500kVA Precision AC Test Transformer

Laboratory-Grade Accuracy for Ultra-High Voltage Applications

Core Specifications

ParameterValueIndustry Advantage
Rated Capacity500 kVACompact power density
Output Voltage500 kVHighest standard test class
Output Current1 APrecision measurement range
Frequency50 HzGlobal compatibility
ConfigurationSingle Phase, Cylindrical TankOptimized field deployment
Weight16,000 kg20% lighter than competitors

Revolutionary Winding System

Triple-Winding Architecture

Winding TypeVoltageCurrentFunctionality
Excitation (2x)3 kV83.3 AConfigurable input (series/parallel)
High Voltage500 kV1 APrecision test output
Accumulator3 kV83.3 AEnergy storage & stabilization

Safety Integration

  • Ground-Fault Protection: HV terminal earthed via 5/5A CT (real-time current monitoring)

  • Surge Protection: Integrated 3kV arresters on excitation/transfer windings

  • Dielectric Safety: 550kV/60s overvoltage withstand (exceeds IEC 60060-1)


Performance Excellence

ParameterSpecificationTest Standard
Partial Discharge (PD)<5pC @ 500kV, <2pC @ 400kVIEC 60270
Waveform Distortion≤3% THDIEEE 519
Dielectric Loss (tan δ)<0.5%IEC 60894
Noise Level≤60 dB @ 4mISO 3744
Temperature RiseWinding: ≤65K, Oil: ≤55KIEC 60076-2
Impedance Voltage≤10%IEC 60076-5

Operational Capabilities


✅ **Duty Cycle:**  
   → 100% load: 60 minutes ON / 60 minutes OFF  
   → 80% load: Continuous operation  

✅ **Robust Overload Protection:**  
   → 150% current for 3 minutes (winding integrity guaranteed)  
   → 110% voltage (550kV) for 60 seconds  

✅ **Safety Compliance:**  
   → 18kV/1min LV-to-earth insulation  
   → Dual surge arresters  
   → Oil injection/release ports

Technical Superiority

1. Unmatched PD Performance

Industry-leading <2pC PD at 400kV - essential for cable/GIS testing per IEC 62067

2. Precision Measurement

Integrated 1000:1 measurement winding enables ±0.1% voltage accuracy

3. Advanced Safety Systems

  • Ground-fault monitoring via HV CT (unique to LQTT series)

  • Dual-redundant surge protection

4. Thermal Resilience

Patented cooling design maintains 65K rise at 500kV - 20% better than industry average


Target Applications

  • Certification Labs: Type testing of 550kV class equipment

  • Cable Manufacturers: PD mapping of HVDC transmission cables

  • Research Institutions: Insulation material development

  • Utility Companies: On-site commissioning of EHV substations


Physical Specifications

🔹 **Dimensions:** Ø2100/Ø2400 × 4500 mm  
🔹 **Weight:** 16,000 kg  
🔹 **Cooling:** ONAN (Oil-Natural Air-Natural)  
🔹 **Color:** Customizable (RAL palette)  
🔹 **Connections:** Dual 3kV inputs + measurement taps

Compliance Statement

*"Engineered to exceed IEC 60060-1 and IEEE C57.12.00 standards for high-voltage test equipment. With revolutionary <2pC PD performance and integrated safety monitoring, this transformer delivers laboratory-grade precision in field-testing environments."*


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message