High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kV Range

LQTT 1250kV/1250kVA Ultra-HV Test Transformer | IEC 60270-Compliant System

1250kVA cascaded AC test transformer for extreme dielectric testing. Features <3pC partial discharge at 1000kV, ONAN cooling, and 1375kV surge capacity. Certified to IEC 60060-1 for EHV equipment validation.


>>>WhatsApp Communication<<<

Product Details

Product Tags

Core System Specifications

ParameterValueStandard
ConfigurationTwo-stage cascade (625kV ×2)Cylinder design
Rated Capacity1250kVAIEC 60076-1
Voltage/Current1250kV / 1A HV
3kV / 416.7A LV
IEC 60060-1
Partial Discharge<5pC @ 1250kV
<3pC @ 1000kV
IEC 60270 Class II
Waveform Distortion≤3%IEEE 1894
Dielectric Loss<0.5% @ 20°CIEC 60247
Overload Capacity120% current (1.2A/300s)
110% voltage (1375kV/60s)
IEC 60076-11

Stage-Wise Technical Specifications

Upper Stage: HCTT625kVA/625kV-1

- **Input/Output:**  
  LV: 3kV/208.3A → HV: 625kV/1A  
- **Insulation Resistance:**  
  >2500MΩ (HV-LV-earth)  
- **Thermal Limits:**  
  Winding ΔT <65K, Oil ΔT <55K  
- **Duty Cycle:**  
  8×1hr cycles daily (1hr ON/OFF)

Sub Stage: HCTT-1250kVA/625kV-1

- **Power Handling:**  
  LV: 3kV/416.7A → HV: 625kV/1A  
- **Oil Specifications:**  
  - Acetylene-free  
  - Pour point >40°C  
  - Dielectric loss <0.5% @ 90°C  
- **Critical Protection:**  
  5/5A CT-monitored HV grounding

Certified Safety & Performance

  • Voltage Stability:
    ≤5% deviation in cascade operation

  • Environmental Resilience:

    • Noise: ≤65dB(A) @ 4m (ISO 3746)

    • Cooling: ONAN (Oil Natural Air Natural)

  • Insulation Integrity:

    • 10kV/1min (LV-HV-shell)

    • 5kV/1min (measurement windings)

  • Surge Protection:
    Integrated arresters on all windings


Compliance Framework

- **Partial Discharge:** IEC 60270 Class II  
- **Insulation Coordination:** IEC 60071-1  
- **Safety:** IEC 61010-1 Cat IV  
- **Oil Testing:** IEC 60156 + ASTM D877  
- **Temperature Rise:** IEC 60076-7

Technical Advantages

  • Extreme Voltage Capacity:
    1375kV surge withstand (110% overload)

  • Precision Diagnostics:
    PD detection <3pC @ 1000kV

  • Robust Thermal Design:
    Certified 8-cycle daily operation at 1250kV

  • Measurement Integrity:
    ≤3% waveform distortion under load


Operational FAQs (Snippet-Optimized)

Q: Maximum ambient temperature for full-load operation?
*A: Rated for 45°C ambient (IEC 60076-12) with ΔT safeguards.*

Q: Oil maintenance protocol?
*A: Replace when dielectric strength <30kV/mm (IEC 60296) or DGA shows acetylene.*

Q: Calibration interval for PD measurement?
*A: Annual calibration per IEC 60270 using NIST-traceable pulse generators.*


>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<