200kV ~ 400kV Range
LQHVF 350kV/3000pF High-Capacitance Voltage Divider
Industrial-grade capacitive divider with 3000:1 ratio, <0.2% dielectric loss, and scalable corona-free connections for precision high-voltage measurement
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 350kV AC (50Hz) |
Nominal Capacitance | 3000pF ±3% |
Dividing Ratio | 3000:1 |
Dielectric Loss (tanδ) | <0.2% |
Partial Discharge | ≤5pC @ 350kV (100%) ≤3pC @ 280kV (80%) |
Measuring Accuracy | ≤±1% |
Insulation Withstand | 385kV for 1 minute (no discharge) |
Continuous Operation | 60 minutes @ rated voltage |
Cooling System | ONAN (Oil Natural Air Natural) |
Dimensions | Base/Top Diameter: 300mm/1100mm Height: 3510mm |
Weight | <300kg |
Advanced Design Features
High-Capacitance Precision
3000pF design enables superior signal capture:
Enhanced signal-to-noise ratio
Improved transient response
Stable 3000:1 dividing ratio
Frequency response: 15Hz - 500Hz
Transport-Optimized Structure
Field-deployable modular design:
Removable aluminum corona rings
Stabilizing pedestal with quick-release
Compact shipping configuration
Weight <300kg
Scalable Measurement System
Flexible connection options:
Corona-free HV terminals
Single-stage and two-stage measurement
Special shielded lead-wire system
Variable frequency power compatibility
Performance Validation
Rigorous Testing Protocol
Partial discharge ≤3pC @ 80% rated voltage (IEC 60270)
Dielectric loss <0.2% at 50Hz (IEC 60247)
385kV/1min insulation withstand with zero discharge
Thermal stability: <3°C temperature rise during operation
Ratio accuracy maintained within 0.8% from -25°C to +55°C
IEC 60270 IEC 60060-1 IEC 60060-2 IEC 61869-11
Compact Dimensions for High Capacity
Optimized footprint despite 3000pF capacitance:
Base diameter: 300mm
Top corona ring diameter: 1100mm
Total height: 3510mm
Weight: <300kg
Modular design reduces shipping volume by 35% compared to conventional units
Industrial Applications
Power Transformer Testing
Precision measurement for:
Dielectric response analysis
Partial discharge localization
Impulse withstand verification
High-Energy Research
Critical applications:
Pulsed power systems
Plasma physics experiments
Dielectric material studies
Field Commissioning
On-site HV system verification:
Substation equipment diagnostics
Cable termination testing
Renewable energy farm commissioning
Operational Advantages
Enhanced Safety Systems
Automatic discharge circuit (τ ≤ 60s)
360° grounding terminals
Oil level/temperature monitoring
Pressure relief mechanisms
Reduced Maintenance
Hermetically sealed oil system
Corrosion-resistant materials
10-year dielectric fluid stability
Field-replaceable modules