200kV ~ 400kV Range
LQHVF 350kV/10000pF High-Capacitance Voltage Divider
Industry-leading 10,000pF capacitive divider with ≤2pC partial discharge at 350kV, 2000:1 ratio, and scalable corona-free connections
Technical Specifications
Parameter | Specification | Testing Standard |
---|---|---|
Rated Voltage | 350kV AC (50Hz) | IEC 60060-1 |
Nominal Capacitance | 10000pF ±3% | IEC 60358 |
Dividing Ratio | 2000:1 | - |
Dielectric Loss (tanδ) | <0.2% | IEC 60247 |
Partial Discharge (PD) | ≤2pC @ 350kV | IEC 60270 |
Measuring Accuracy | ≤±1% | IEC 60060-2 |
Continuous Operation | 60 min @ 100% rated voltage/current | IEC 61180 |
Insulation Withstand | 385kV for 1 minute (no discharge) | IEC 60060-1 |
Cooling System | ONAN (Oil Natural Air Natural) | IEC 60296 |
Advanced Design Features
High-Capacitance Precision
10,000pF design enables superior signal integrity:
Enhanced signal-to-noise ratio for weak measurements
Improved transient response (rise time
<5μs)<>Stable 2000:1 dividing ratio
Bandwidth: DC - 1kHz
Scalable HV Connections
Flexible measurement configurations:
Corona-free HV terminals
Single-stage and two-stage serial measurement
Special shielded lead-wire system
Variable frequency power compatibility (30-150Hz)
Transport-Optimized System
Field-deployable modular design:
Removable aluminum corona rings
Quick-release stabilizing pedestal
Component-based packaging
45-minute assembly time
Performance Validation
Certified Testing Protocol
Partial discharge ≤2pC verified at 350kV (IEC 60270 Class I)
Dielectric loss <0.2% at 50Hz (IEC 60247)
385kV/1min insulation withstand with zero discharge
Thermal stability: ΔT <3°C during 60-min operation
Ratio accuracy maintained within 0.8% from -25°C to +55°C
IEC 60270 IEC 60060-1 IEC 60060-2 IEC 61180
Measurement Capabilities
Single-Stage Configuration
Direct measurement up to 350kV
Special shielded lead-wire system
Accuracy: ≤±1%
Ideal for laboratory precision tests
Two-Stage Serial Connection
Extended voltage measurement capability
Phase-synchronized outputs
Corona-free HV terminals
Field testing applications
Variable Frequency Operation
Compatible with 30-150Hz power sources for specialized applications:
Cable withstand testing (VLF)
Transformer diagnostic testing
Dielectric spectroscopy
Industrial Applications
High-Energy Research
Critical applications:
Pulsed power systems
Plasma physics experiments
Dielectric material studies
Particle accelerator diagnostics
Power Equipment Testing
Precision validation:
Ultra-high voltage transformers
GIS partial discharge mapping
HVDC converter station testing
Cable system commissioning
Calibration Laboratories
Reference-standard applications:
National Metrology Institute traceability
HV meter certification
Impulse measurement validation
Standard reference dividers